GV

GeezerVison

The World Wide Web, restored to 800 pixels of glory.

Home|About|Gaming cabinet|Archives|How it works|Starter sites

On this site

  • niphlem
  • User guide
  • Tutorials
  • API
  • Citing niphlem
  • View page source

This view

  • Original page
  • New address

GeezerVison is showing coaxlab.github.io — niphlem: NeuroImaging-oriented Physiological Log Extraction for Modeling — niphlem 0.0.1-beta documentation

niphlem: NeuroImaging-oriented Physiological Log Extraction for Modeling

niphlem is a toolbox that extracts physiological signals recorded coincidentally with functional MRI data and estimates the signal phases so that they can be used as a covariate in subsequent analyses.

niphlem can generate multiple models of physiological noise to include as regressors from either ECG, pneumatic breathing belt or pulse-oximetry data. These are described in detail in Verstynen and Deshpande (2011).

Briefly, niphlem implements two physiological models for regressors generation:

  • RETROICOR: A phasic decomposition method that isolates the fourier series that best describes the spectral properties of the input signal. This was first described by Glover and colleagues (2000).

  • Variation Models: For low frequency signals (like the pneumatic belt and low-pass filtered pulse-oximetry) this does the combined respiration variance and response function described by Birn and colleagues (2006, 2008). For high frequency signals (i.e., ECG or high-pass filtered pulse-oximetry), this generates the heart-rate variance and cardiac response function described by Chang and colleagues (2009).

Installation

niphlem can be easily installed through pypi as follows:

pip install -U niphlem

References:

  • Verstynen TD, Deshpande V. Using pulse oximetry to account for high and low frequency physiological artifacts in the BOLD signal. Neuroimage. 2011 Apr 15;55(4):1633-44.

  • Chang C, Cunningham JP, Glover GH. Influence of heart rate on the BOLD signal: the cardiac response function. Neuroimage. 2009 Feb 1;44(3):857-69.

  • Birn RM, Smith MA, Jones TB, Bandettini PA. The respiration response function: the temporal dynamics of fMRI signal fluctuations related to changes in respiration. Neuroimage. 2008;40(2):644-654.

Contents

  • User guide
    • 1-Intro to Niphlem
    • 2-Physiological Signal
    • 3-RETROICOR Models
    • 4-Variation Models
    • 5-Reports
  • Tutorials
    • Tutorial 1: QC report for ecg data
    • Tutorial 2: Load physio data in BIDS format
    • Tutorial 3: Regressors from ecg data
    • Tutorial 4: Regressors from pulse oximeter data
  • API
    • Input data
    • Models
    • Report
  • Citing niphlem
You are visitor 01402775 — GeezerVison does not store the pages you look up.
Best viewed with Netscape Navigator 4.7 or Internet Explorer 6 at 800×600. No cookies required.