GV

GeezerVison

The World Wide Web, restored to 800 pixels of glory.

Home|About|Gaming cabinet|Archives|How it works|Starter sites

On this site

  • Sign in
  • ActionsCI/CD and automation
  • CodespacesCloud development environments
  • All Features
  • Documentation
  • Training
  • Certifications
  • Build with Copilot
  • Customize Copilot
  • Integrations
  • Trending repos
  • GitHub Sponsors
  • Developer articles
  • Enterprises

This view

  • Original page
  • New address

GeezerVison is showing github.com — a320-cli/mcp/README.md at main · Santisoutoo/a320-cli

Expand file tree

/

README.md

Copy path
More file actions
More file actions

Latest commit

 

History

History
History
152 lines (116 loc) · 5.89 KB
/

README.md

Copy path

File metadata and controls

152 lines (116 loc) · 5.89 KB
Raw
Copy raw file
Download raw file
Outline
Edit and raw actions

a320-mcp — the LLM's window onto the aircraft

An MCP server exposing the headless A320 systems core, so an LLM agent can fly the closed loop: observe the ECAM, reason over the procedure, act on the switches, advance time, observe again.

Same core the CLI drives — two frontends, one API. Every tool here is a 1:1 mapping onto a320_sim.Sim; there is no simulation logic in this package.

Install

Needs Python ≥ 3.10 (the MCP SDK's floor; the rest of the repo is ≥ 3.9). Install the bindings first — they are not on PyPI:

pip install -e bindings/
pip install -e mcp/

Run

a320-mcp                            # cold & dark (default)
a320-mcp --start apu-running        # APU started and feeding the AC network
a320-mcp --start engines-running    # both engines at idle powering everything

The server speaks stdio, so you don't normally run it by hand — a client launches it and talks over the pipe.

--start apu-running takes ~60 s of simulated time at boot (a few seconds of wall clock) to spin the APU up before serving; --start engines-running runs the full cold & dark → engines running sequence (~6 min simulated: APU, APU bleed, both engine starts, APU shutdown) and hands over a healthy aircraft on its engine generators with a clean ECAM. The scenario is the harness's job, not the agent's.

Point a client at it

The repo ships a .mcp.json that registers this server:

{
  "mcpServers": {
    "a320": {
      "command": "a320-mcp",
      "args": ["--start", "apu-running"]
    }
  }
}

The client spawns a320-mcp, so it has to be on the PATH of the process that launches the client — activate the virtualenv you installed it into before starting the client, or point command at the executable directly (.venv/Scripts/a320-mcp.exe on Windows, .venv/bin/a320-mcp elsewhere).

MCP servers are read at client startup, so a client that was already running won't see it until you restart it.

Then hand it the scenario:

The APU generator just failed. Deal with it.

The agent has the ECAM and the switches — and nothing that tells it what broke.

Tools

Tool What it does
read_ecam Active warnings and cautions, worst first — the agent's primary observation
read_state Read named state variables (takes a list)
snapshot Discover state variables by name filter
list_controls The curated cockpit controls you can actuate
list_failures The catalog of what can break
set_control Flip a switch or pushbutton
advance Advance simulated time — nothing takes effect until you do
inject_failure Break something (reversibly)
clear_failure Repair it

Valid control names and failure ids are baked into the tool schemas as enums, generated from the catalogs — the model cannot name something that isn't there.

Two tools deliberately do not exist. The core can report which failures are active and can list every variable; neither is exposed. The first would hand the agent the answer it is supposed to diagnose from the ECAM; the second would bury the context window under hundreds of names. See D-016 in docs/decisiones.md.

Tool profiles. The table above is the interactive profile — what the stdio entry point serves. The server is built by create_server(sim, profile=...); the Phase 5 benchmark runner builds one with profile="benchmark", which withholds inject_failure/clear_failure (the injected failure is the exam — an agent that can repair the fault is not flying the procedure) and adds report_done(diagnosis, actions_summary) as the explicit end-of-episode channel. Profiles change which tools exist, never what a tool does.

Worked example: the agent loop

What a client sees driving the apu-running scenario:

> read_ecam
  []                                      # healthy: the APU feeds the network

  (a failure is injected by the harness)

> read_ecam
  [{"message": "AC ESS BUS FAULT", "severity": "caution", "system": "ELEC", "source": "vendor_flag"},
   {"message": "APU GEN FAULT",    "severity": "caution", "system": "ELEC", "source": "vendor_flag"}]

> snapshot "_BUS_IS_POWERED"
  {"ELEC_AC_1_BUS_IS_POWERED": 0.0,       # the whole AC network is gone...
   "ELEC_AC_2_BUS_IS_POWERED": 0.0,
   "ELEC_AC_ESS_BUS_IS_POWERED": 0.0,
   "ELEC_DC_1_BUS_IS_POWERED": 0.0,       # ...and DC 1/2 with it: they feed via the TRs
   "ELEC_DC_2_BUS_IS_POWERED": 0.0,
   "ELEC_DC_BAT_BUS_IS_POWERED": 1.0,     # batteries hold the essential DC —
   "ELEC_DC_ESS_BUS_IS_POWERED": 1.0}     # which is why the ECAM is still readable

> set_control apu_gen 0                   # the faulty source out of the loop
> set_control ext_pwr_avail 1             # ask for a GPU
> set_control ext_pwr 1                   # put it on the network
> advance 3
> read_ecam
  []                                      # clear: AC 1/2/ESS and DC 1/2 all back

Losing the APU generator raises two cautions — the source fault and the downstream AC ESS bus — because it was the only AC source. That cascade is the scenario, and dealing with it is the task.

The engine generators are no help here (no engines running), so on the ground the answer is external power. Note ext_pwr_avail is a world control, not a cockpit one: a real crew asks for a ground power unit, they don't plug it in themselves. A Phase 5 scenario should pre-set its world state rather than hand it to the agent — see the Phase 3 closure note in docs/decisiones.md.

Tests

They spawn the server as a subprocess and talk to it over the real stdio protocol, so what is checked is what an agent would see:

python mcp/tests/test_server.py     # or: pytest mcp/tests/

License

GPLv3 — the server drives the a320_sim extension, which links the vendored FlyByWire crates and inherits their license.

You are visitor 01402792 — GeezerVison does not store the pages you look up.
Best viewed with Netscape Navigator 4.7 or Internet Explorer 6 at 800×600. No cookies required.