GV

GeezerVison

The World Wide Web, restored to 800 pixels of glory.

Home|About|Gaming cabinet|Archives|How it works|Starter sites

On this site

  • Sign in
  • ActionsCI/CD and automation
  • CodespacesCloud development environments
  • All Features
  • Documentation
  • Training
  • Certifications
  • Build with Copilot
  • Customize Copilot
  • Integrations
  • Trending repos
  • GitHub Sponsors
  • Developer articles
  • Enterprises

This view

  • Original page
  • New address

GeezerVison is showing github.com — bitengine-hub-hardware/docs/interfaces.md at main · bitEngineTech/bitengine-hub-hardware

Expand file tree

/

interfaces.md

Copy path
More file actions
More file actions

Latest commit

 

History

History
History
193 lines (144 loc) · 8.94 KB
/

interfaces.md

Copy path

File metadata and controls

193 lines (144 loc) · 8.94 KB
Raw
Copy raw file
Download raw file
Outline
Edit and raw actions

Interfaces, indicators and specifications

This page describes what is on the outside of the bitEngine Hub and how the main blocks are connected inside. For the overall structure see the block diagram.

The status-LED and button behaviour described here is implemented in the ESP32-C5 firmware and reflects the current firmware; if the two ever disagree, the firmware is authoritative.

Dimensions, mounting and the positions of connectors and light pipes on the enclosure will be published with the enclosure files.

External connectors

Connector Type Function
Ethernet RJ45, shielded 10/100BASE-TX Ethernet (DM9051, SPI-attached to the ESP32-C5) and IEEE 802.3af PoE power input
USB-C USB Type-C receptacle 5 V DC power input (sink only), and USB 2.0 Full Speed to the ESP32-C5's built-in USB Serial/JTAG controller for flashing, serial console and debugging
ANT1 RP-SMA female (reverse polarity) Zigbee antenna — EFR32MG24, 2.4 GHz
ANT2 RP-SMA female (reverse polarity) Thread + Wi-Fi antenna — ESP32-C5 (802.15.4 at 2.4 GHz and Wi-Fi at 5 GHz), via the module's U.FL connector and a short internal coaxial pigtail

Both antenna connectors are RP-SMA, not standard SMA: antennas and test cables need an RP-SMA plug. A standard SMA antenna will not mate. The hub uses two detachable external 2.4 / 5 GHz dual-band antennas of the same type, one per radio, so Zigbee and Thread never share an antenna or a radio.

The hub has one push button and four RGB status LEDs; they are described below.

Power

Item Value
PoE input IEEE 802.3af powered device; nominal 48 V DC (37–57 V at the powered device, per 802.3af). TMI7321 PD interface and flyback DC-DC converter to 5 V
USB-C input 5 V DC, power sink only
Both inputs connected Allowed. The two 5 V sources are combined by diode OR-ing; PoE takes priority
Internal rails 5 V (also supplies the WS2812B LEDs); 3.3 V from a synchronous buck converter for all ICs

Radios

Radio Chip Antenna Band Use
Zigbee 3.0 EFR32MG24B020 (integrated PA, up to +19.5 dBm) ANT1 2405–2480 MHz, IEEE 802.15.4 channels 11–26 Zigbee coordinator (EmberZNet NCP), used by Zigbee2MQTT or ZHA through the hub
Thread ESP32-C5 (IEEE 802.15.4 radio) ANT2 2405–2480 MHz, IEEE 802.15.4 channels 11–26 Thread Border Router running on the hub
Wi-Fi 6 ESP32-C5 ANT2 5 GHz only Network uplink as an alternative to Ethernet (client mode). When the hub has no network connection it opens a temporary 5 GHz setup access point on channel 36
Wi-Fi 2.4 GHz ESP32-C5 — — Present in hardware, disabled in firmware so the 2.4 GHz band stays clear for Zigbee and Thread
Bluetooth LE ESP32-C5 and EFR32MG24 — — Present in hardware, not enabled by the firmware
  • Zigbee (EFR32MG24) and Thread (ESP32-C5) are separate chips with separate antennas and can operate at the same time on different channels.
  • 5 GHz Wi-Fi and Thread share the ESP32-C5's RF path and are time-shared by its coexistence mechanism.
  • Zigbee and Thread transmit power limits follow the regulatory region selected in the hub's settings.

Internal links

Link Details
ESP32-C5 ↔ EFR32MG24 UART at 460 800 baud with RTS/CTS hardware flow control, carrying EZSP. The ESP32-C5 also controls the EFR32MG24's reset and boot-select lines, so it can update the Zigbee firmware over the same UART link
ESP32-C5 ↔ DM9051 SPI
ESP32-C5 → status LEDs One data line to a daisy chain of four WS2812B LEDs
Button → ESP32-C5 One digital input

There is no external flash: the ESP32-C5-WROOM-1U-N8R8 module provides 8 MB flash and 8 MB PSRAM, and the EFR32MG24 uses its internal 1536 kB flash.

Programming and debug access

Chip Access
ESP32-C5 USB-C (built-in USB Serial/JTAG): firmware flashing, serial console, JTAG debugging. The board has no BOOT button
EFR32MG24 Normally updated by the ESP32-C5 over the UART link. For direct programming, SWD test pads are provided inside the enclosure (not user-accessible)

Pad locations and pinouts will be published with the schematics.

Status LEDs

Four RGB LEDs, labelled SYS, ZIGBEE, THREAD and NET, in that order.

The three function LEDs (ZIGBEE, THREAD, NET) share one colour scheme:

Indication Meaning
Solid green Working normally
Yellow, slow blink Needs attention: in progress, degraded, or waiting for something
Red, slow blink Fault
Off Function not running

The LEDs show the current state, not only activity, so a healthy idle hub shows green rather than going dark.

"Slow blink" is about 1 Hz (0.5 s on, 0.5 s off); "fast flash" is about 3 Hz (0.15 s on, 0.15 s off).

SYS — whole device

Indication Meaning
Solid green Normal operation
Solid yellow Starting up, or a firmware update has just finished and the hub is about to restart
Yellow, slow pulse (bright / dim) Setup access point is active and waiting for configuration
Blue, slow pulse (bright / dim) Connecting to the network, or reconnecting after losing it
Purple, fast flash Firmware update in progress — do not remove power
Red, fast flash for a few seconds An error event, after which the LED returns to its normal indication (see below)

The red flash lasts different times depending on the cause:

Duration Cause
3 s Network connection lost (SYS then shows blue while reconnecting)
3 s Firmware update failed (the hub keeps running the previous firmware)
2 s The Zigbee chip was reset
5 s A setting could not be saved to flash

ZIGBEE

Indication Meaning
Solid green Zigbee chip is working and a Zigbee host (Zigbee2MQTT or ZHA) is connected
Short blue blinks over green Zigbee traffic through the hub
Yellow, slow blink Zigbee chip is working, but no Zigbee host is connected
Red, slow blink Zigbee chip is not responding
Off Zigbee bridge disabled in the settings

THREAD

Indication Meaning
Solid green The hub is attached to its Thread network and border routing is running
Yellow, slow blink Not yet attached or dropped off the Thread network, or border routing is temporarily stopped (for example while the uplink switches between Ethernet and Wi-Fi)
Red, slow blink The 802.15.4 radio has stopped sending and receiving; the firmware tries to recover automatically
Off The Thread Border Router is not running

This LED shows only the hub's own Thread state. A green THREAD LED does not mean every Thread device is online; devices may be attached to other Thread routers.

NET — network uplink

Indication Meaning
Solid green Online (Ethernet or Wi-Fi)
Short white blinks over green Network traffic (Zigbee bridge, web interface, MQTT, webhooks), at most one blink every 0.4 s
Yellow, slow blink Connecting, reconnecting, or waiting for network setup
Red, slow blink No network

Brightness and night mode

LED brightness and a night mode are set in the web interface. During the night-mode time window all four LEDs are off; this is normal. The button feedback described below is still shown during night mode and at full brightness.

Button

One push button. The action depends on how long it is held:

Hold time Action
Less than 0.1 s Ignored (accidental touch)
0.1 – 2 s Restart the hub
2 – 10 s No action (guard band against accidental factory reset). Also used as a physical confirmation when an action started in the web interface asks for one
10 – 20 s Factory reset
20 s or more Treated as a stuck button and ignored

While the button is held, all four LEDs show what releasing it will do:

LEDs while holding Releasing now
Normal display (up to 2 s) Restarts the hub (if held for at least 0.1 s)
All solid red (from 2 s) Does nothing — the restart window has passed; keep holding for factory reset
All alternating red / white, fast (from 10 s) Performs a factory reset

To cancel after the LEDs have started alternating red and white, keep holding until 20 s have passed; the press is then ignored.

A factory reset from the button clears the Wi-Fi settings, the password and the configuration, and keeps the Thread network. The Zigbee network is stored in the EFR32MG24 and is not affected.

Environmental

Design specification:

Item Value
Use Indoor, fixed installation
Operating temperature 0 to +45 °C
Storage temperature −20 to +60 °C
Humidity 10–90 % RH, non-condensing

Mechanical

  • Production enclosure: aluminum extrusion. Prototype units use a 3D-printed enclosure.
  • Dimensions, weight, mounting, and the positions of connectors and light pipes will be published with the enclosure files.