GV

GeezerVison

The World Wide Web, restored to 800 pixels of glory.

Home|About|Gaming cabinet|Archives|How it works|Starter sites

On this site

  • Sign in
  • ActionsCI/CD and automation
  • CodespacesCloud development environments
  • All Features
  • Documentation
  • Training
  • Certifications
  • Build with Copilot
  • Customize Copilot
  • Integrations
  • Trending repos
  • GitHub Sponsors
  • Developer articles
  • Enterprises

This view

  • Original page
  • New address

GeezerVison is showing github.com — SimpleSOAP/src/ble/adapters.ts at main · jfweleber/SimpleSOAP

Expand file tree

/

adapters.ts

Copy path
More file actions
More file actions

Latest commit

 

History

History
History
412 lines (366 loc) · 14.2 KB
/

adapters.ts

Copy path

File metadata and controls

412 lines (366 loc) · 14.2 KB
Raw
Copy raw file
Download raw file
Open symbols panel
Edit and raw actions
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
/**
* Adapter registry for BLE vitals monitors.
*
* Two adapters implement published Bluetooth SIG profiles. The other five
* implement vendor framing carried over a serial-style characteristic, derived
* from protocol analysis; each is marked `verified: false` until it has been
* confirmed against real hardware.
*
* Adding a device means adding one entry here. Nothing else needs to change.
*/
import type { Adapter, Measurement, ScannedDevice } from './types'
import { emptyMeasurement } from './types'
import {
CHOICEMMED_ADVERT,
FFE0_NOTIFY,
FFE0_SERVICE,
FFF0_NOTIFY,
FFF0_SERVICE,
HEART_RATE_MEASUREMENT,
HEART_RATE_SERVICE,
ISSC_NOTIFY,
ISSC_SERVICE,
JUMPER_NOTIFY,
JUMPER_SERVICE,
NUS_NOTIFY,
NUS_SERVICE,
PLX_CONTINUOUS_MEASUREMENT,
PLX_SERVICE,
VIATOM_NOTIFY,
VIATOM_SERVICE,
} from './uuid'
const advertises = (d: ScannedDevice, uuid: string) => d.serviceUUIDs?.includes(uuid) ?? false
const namedLike = (d: ScannedDevice, patterns: RegExp[]) =>
!!d.name && patterns.some((p) => p.test(d.name as string))
/** A reading where the probe is on but sees nothing — distinct from a bad frame. */
function noContact(): Measurement {
return { ...emptyMeasurement(), sensorContact: false }
}
// ---------------------------------------------------------------------------
// Standard GATT — Heart Rate Service 0x180D
// ---------------------------------------------------------------------------
/**
* Heart Rate Measurement, characteristic 0x2A37.
*
* Flags byte drives a variable layout:
* bit 0 heart rate is uint16 (else uint8)
* bit 1 sensor contact detected
* bit 2 sensor contact supported — bit 1 is meaningless without this
* bit 3 energy expended field present (uint16)
* bit 4 RR interval fields present (uint16 each, units of 1/1024 s)
*/
export const heartRateAdapter: Adapter = {
id: 'ble_hr',
name: 'Heart Rate Monitor',
kind: 'heartRate',
provides: ['heartRate', 'rrIntervals'],
scanServiceUUIDs: [HEART_RATE_SERVICE],
verified: false,
matches: (d) => advertises(d, HEART_RATE_SERVICE),
target: () => ({ service: HEART_RATE_SERVICE, characteristic: HEART_RATE_MEASUREMENT }),
parse(view) {
if (view.byteLength < 2) return null
const flags = view.getUint8(0)
const wide = (flags & 0x01) !== 0
const contactSupported = (flags & 0x04) !== 0
const contactDetected = (flags & 0x02) !== 0
const hasEnergy = (flags & 0x08) !== 0
const hasRR = (flags & 0x10) !== 0
let offset = 1
let heartRate: number
if (wide) {
if (view.byteLength < offset + 2) return null
heartRate = view.getUint16(offset, true)
offset += 2
} else {
heartRate = view.getUint8(offset)
offset += 1
}
if (hasEnergy) offset += 2
const rrIntervals: number[] = []
if (hasRR) {
while (offset + 1 < view.byteLength) {
// transmitted in 1/1024 s units
rrIntervals.push((view.getUint16(offset, true) / 1024) * 1000)
offset += 2
}
}
return {
...emptyMeasurement(),
heartRate,
rrIntervals,
sensorContact: contactSupported ? contactDetected : null,
}
},
}
// ---------------------------------------------------------------------------
// Standard GATT — Pulse Oximeter Service 0x1822
// ---------------------------------------------------------------------------
/**
* Decode an IEEE-11073 16-bit SFLOAT.
*
* Layout is a signed 4-bit exponent in the high nibble over a signed 12-bit
* mantissa. Five mantissa values are reserved for non-numeric states
* (+INFINITY, NaN, NRes, reserved, -INFINITY) and mean "no usable reading".
*/
function decodeSFloat(raw: number): number | null {
const mantissa = raw & 0x0fff
if (mantissa >= 0x07fe && mantissa <= 0x0802) return null
const rawExponent = (raw >> 12) & 0x0f
const exponent = rawExponent >= 0x08 ? rawExponent - 0x10 : rawExponent
const value = mantissa >= 0x0800 ? mantissa - 0x1000 : mantissa
return value * Math.pow(10, exponent)
}
/** PLX Continuous Measurement, characteristic 0x2A5F. */
export const plxAdapter: Adapter = {
id: 'ble_plx',
name: 'Pulse Oximeter (standard)',
kind: 'pulseOximeter',
provides: ['spo2', 'heartRate'],
scanServiceUUIDs: [PLX_SERVICE],
verified: false,
matches: (d) => advertises(d, PLX_SERVICE),
target: () => ({ service: PLX_SERVICE, characteristic: PLX_CONTINUOUS_MEASUREMENT }),
parse(view) {
// flags @0, then SpO2 and pulse rate as consecutive SFLOATs
if (view.byteLength < 5) return null
const spo2 = decodeSFloat(view.getUint16(1, true))
const pulse = decodeSFloat(view.getUint16(3, true))
if (spo2 === null || pulse === null) return noContact()
return { ...emptyMeasurement(), spo2, heartRate: pulse, sensorContact: true }
},
}
// ---------------------------------------------------------------------------
// Vendor — BCI protocol over Microchip/ISSC transparent UART (BerryMed)
// ---------------------------------------------------------------------------
const BERRYMED_NAMES = [/^BerryMed/i, /^BM\d/i]
/**
* A BCI frame is five bytes, and only the first has bit 7 set. That bit is
* the frame boundary: the transparent UART carries a byte stream, so one
* notification holds several frames and starts wherever the last one ended.
*
* 0 1sss ssss sync; bits 0–3 signal strength
* 1 0ppp pppp pleth (0–100)
* 2 0Rfs bbbb R = pulse rate bit 7, f = no finger, s = searching, bar graph
* 3 0rrr rrrr pulse rate bits 0–6
* 4 0ooo oooo SpO₂, 127 when there is no reading
*
* The first version of this read offsets 3 and 4 of the notification, which
* is right only when a frame happens to start at byte 0. Against a BM1000C
* it mostly did not, and the screen showed an SpO₂ of 133 — a sync byte,
* read as a number. Perfusion index is not in this frame; the manufacturer's
* app shows one, so the device carries it somewhere else, still to be found.
*/
const BCI_FRAME = 5
function bciFrameAt(view: DataView, i: number): boolean {
if (i + BCI_FRAME > view.byteLength) return false
if ((view.getUint8(i) & 0x80) === 0) return false
for (let k = 1; k < BCI_FRAME; k++) if (view.getUint8(i + k) & 0x80) return false
return true
}
export const berryMedAdapter: Adapter = {
id: 'ble_bci',
name: 'BerryMed / BCI',
kind: 'pulseOximeter',
provides: ['spo2', 'heartRate'],
scanServiceUUIDs: [ISSC_SERVICE],
// BM1000C-O, 2026-09-06: pulse and SpO₂ tracked the unit's own display
// once the parser found frame boundaries. Perfusion index is not carried
// in this frame and stays unprovided until its source is known.
verified: true,
matches: (d) => advertises(d, ISSC_SERVICE) || namedLike(d, BERRYMED_NAMES),
target: () => ({ service: ISSC_SERVICE, characteristic: ISSC_NOTIFY }),
parse(view) {
// the newest complete frame in the notification is the reading
let start = -1
for (let i = view.byteLength - BCI_FRAME; i >= 0; i--) {
if (bciFrameAt(view, i)) {
start = i
break
}
}
if (start < 0) return null
const status = view.getUint8(start + 2)
const noFinger = (status & 0x10) !== 0
const pulse = ((status & 0x40) << 1) | (view.getUint8(start + 3) & 0x7f)
const spo2 = view.getUint8(start + 4) & 0x7f
if (noFinger || spo2 === 127 || spo2 === 0 || pulse === 0 || pulse === 255) return noContact()
if (spo2 > 100) return null
return { ...emptyMeasurement(), heartRate: pulse, spo2, sensorContact: true }
},
}
// ---------------------------------------------------------------------------
// Vendor — ChoiceMMed, over Nordic UART
// ---------------------------------------------------------------------------
const CHOICEMMED_NAMES = [/^iP\d+/i]
export const choiceMMedAdapter: Adapter = {
id: 'ble_choicemmed',
name: 'ChoiceMMed',
kind: 'pulseOximeter',
provides: ['spo2', 'heartRate', 'respiratoryRate', 'perfusionIndex'],
scanServiceUUIDs: [NUS_SERVICE],
verified: false,
matches: (d) => advertises(d, CHOICEMMED_ADVERT) || namedLike(d, CHOICEMMED_NAMES),
target: () => ({ service: NUS_SERVICE, characteristic: FFF0_NOTIFY }),
// will not start streaming until this second characteristic is also subscribed
extraSubscriptions: () => [{ service: NUS_SERVICE, characteristic: FFF0_SERVICE }],
parse(view) {
// 13-byte frame, 0x3E leader and 0xF0 terminator
if (view.byteLength !== 13) return null
if (view.getUint8(0) !== 0x3e) return null
if (view.getUint8(12) !== 0xf0) {
// idle frame the device sends with the probe empty
const idle = view.getUint8(8) === 0x20 && view.getUint8(1) === 0 && view.getUint8(3) === 0
return idle ? noContact() : null
}
const spo2 = view.getUint8(1)
const pulse = view.getUint8(3)
if (spo2 === 0 || pulse === 0) return noContact()
const pi = view.getUint8(11)
return {
...emptyMeasurement(),
spo2,
heartRate: pulse,
respiratoryRate: view.getUint8(5),
perfusionIndex: pi > 0 ? pi / 10 : null,
sensorContact: true,
}
},
}
// ---------------------------------------------------------------------------
// Vendor — generic FFE0 serial bridge (HM-10 class modules)
// ---------------------------------------------------------------------------
const FFE0_NAMES = [/^HealthTree/i, /^OXIMETER/i]
export const ffe0Adapter: Adapter = {
id: 'ble_ffe0',
name: 'Generic Oximeter (FFE0)',
kind: 'pulseOximeter',
provides: ['spo2', 'heartRate', 'perfusionIndex'],
scanServiceUUIDs: [FFE0_SERVICE],
verified: false,
matches: (d) => advertises(d, FFE0_SERVICE) || namedLike(d, FFE0_NAMES),
target: () => ({ service: FFE0_SERVICE, characteristic: FFE0_NOTIFY }),
parse(view) {
// 20-byte frame behind an 0xFF 0x44 signature
if (view.byteLength !== 20) return null
if (view.getUint8(0) !== 0xff || view.getUint8(1) !== 0x44) return null
const spo2 = view.getUint8(4)
const pulse = view.getUint8(5)
// 0xFF is the no-data sentinel; anything over 100% is a bad frame
if (spo2 === 0 || spo2 === 0xff || pulse === 0 || pulse === 0xff || spo2 > 100) {
return noContact()
}
// perfusion index spans two bytes, 7 significant bits each
const pi = (view.getUint8(6) & 0x7f) | ((view.getUint8(7) & 0x7f) << 7)
return {
...emptyMeasurement(),
spo2,
heartRate: pulse,
perfusionIndex: pi > 0 ? pi / 100 : null,
sensorContact: true,
}
},
}
// ---------------------------------------------------------------------------
// Vendor — Jumper
// ---------------------------------------------------------------------------
export const jumperAdapter: Adapter = {
id: 'ble_jumper',
name: 'Jumper',
kind: 'pulseOximeter',
provides: ['spo2', 'heartRate', 'perfusionIndex'],
scanServiceUUIDs: [JUMPER_SERVICE],
verified: false,
matches: (d) => advertises(d, JUMPER_SERVICE),
target: () => ({ service: JUMPER_SERVICE, characteristic: JUMPER_NOTIFY }),
parse(view) {
// 4-byte frame behind an 0x81 leader
if (view.byteLength < 4) return null
if (view.getUint8(0) !== 0x81) return null
const pulse = view.getUint8(1)
const spo2 = view.getUint8(2)
if (pulse === 0 || spo2 === 0) return noContact()
const pi = view.getUint8(3)
return {
...emptyMeasurement(),
heartRate: pulse,
spo2,
perfusionIndex: pi > 0 ? pi / 10 : null,
sensorContact: true,
}
},
}
// ---------------------------------------------------------------------------
// Vendor — Viatom / Wellue
// ---------------------------------------------------------------------------
/**
* CRC-8, polynomial 0x8C (reflected 0x31), zero seed.
* Covers every byte of the frame except the checksum itself.
*/
function crc8(bytes: Uint8Array, length: number): number {
let crc = 0
for (let i = 0; i < length; i++) {
crc ^= bytes[i]
for (let bit = 0; bit < 8; bit++) {
crc = crc & 0x01 ? (crc >> 1) ^ 0x8c : crc >> 1
}
}
return crc
}
export const viatomAdapter: Adapter = {
id: 'ble_viatom',
name: 'Viatom / Wellue',
kind: 'pulseOximeter',
provides: ['spo2', 'heartRate'],
scanServiceUUIDs: [VIATOM_SERVICE, NUS_SERVICE],
verified: false,
matches: (d) => advertises(d, VIATOM_SERVICE) || advertises(d, NUS_SERVICE),
// newer units use the Viatom service; older ones fall back to Nordic UART
target: (d) =>
advertises(d, VIATOM_SERVICE)
? { service: VIATOM_SERVICE, characteristic: VIATOM_NOTIFY }
: { service: NUS_SERVICE, characteristic: NUS_NOTIFY },
parse(view) {
// 0xAA 0x55 leader, uint16 length @3, CRC-8 in the final byte
if (view.byteLength < 8) return null
if (view.getUint8(0) !== 0xaa || view.getUint8(1) !== 0x55) return null
const frameLength = 5 + view.getUint16(3, true)
if (view.byteLength < frameLength) return null
const bytes = new Uint8Array(view.buffer, view.byteOffset, view.byteLength)
if (crc8(bytes, frameLength - 1) !== view.getUint8(frameLength - 1)) return null
// packet type 1 is the vitals frame; others are battery, config, etc.
if (view.getUint8(5) !== 0x01) return null
const spo2 = view.getUint8(6)
const pulse = view.getUint8(7)
if (spo2 === 0 || pulse === 0) return noContact()
return { ...emptyMeasurement(), spo2, heartRate: pulse, sensorContact: true }
},
}
// ---------------------------------------------------------------------------
// Registry
// ---------------------------------------------------------------------------
/**
* Order matters. Standard profiles are tried first so a spec-compliant device
* is never claimed by a vendor adapter with a looser match — Viatom in
* particular matches on bare Nordic UART, which many unrelated devices expose.
*/
export const adapters: Adapter[] = [
heartRateAdapter,
plxAdapter,
berryMedAdapter,
jumperAdapter,
ffe0Adapter,
choiceMMedAdapter,
viatomAdapter,
]
/** Every service UUID worth scanning for, deduplicated. */
export function scanServiceUUIDs(): string[] {
return [...new Set(adapters.flatMap((a) => a.scanServiceUUIDs))]
}
/** First adapter that claims the device, or null if nothing recognizes it. */
export function resolveAdapter(device: ScannedDevice): Adapter | null {
return adapters.find((a) => a.matches(device)) ?? null
}
export function adapterById(id: string): Adapter | null {
return adapters.find((a) => a.id === id) ?? null
}
You are visitor 01402792 — GeezerVison does not store the pages you look up.
Best viewed with Netscape Navigator 4.7 or Internet Explorer 6 at 800×600. No cookies required.