GV

GeezerVison

The World Wide Web, restored to 800 pixels of glory.

Home|About|Gaming cabinet|Archives|How it works|Starter sites

On this site

  • Log in
  • Find a journal
  • Publish with us
  • Track your research
  • Saved research
  • Cart
  • Home
  • Biomedical Engineering Letters
  • ORCID: orcid.org/0000-0001-8292-7093
  • Explore all metrics
  • Journals A-Z
  • Books A-Z
  • Subjects A-Z
  • Journal finder

This view

  • Original page
  • New address

GeezerVison is showing link.springer.com — Diffusion-Phys: noise-robust heart rate estimation from facial videos via diffusion models - Biomedical Engineering Letters

Abstract

Remote photoplethysmography (rPPG) offers significant potential for health monitoring and emotional analysis through non-contact physiological measurement from facial videos. However, noise remains a crucial challenge, limiting the generalizability of current rPPG methods. This paper introduces Diffusion-Phys, a novel framework using diffusion models for robust heart rate (HR) estimation from facial videos. Diffusion-Phys employs Multi-scale Spatial-Temporal Maps (MSTmaps) to preprocess input data and introduces Gaussian noise to simulate real-world conditions. The model is trained using a denoising network for accurate HR estimation. Experimental evaluations on the VIPL-HR, UBFC-rPPG and PURE datasets demonstrate that Diffusion-Phys achieves comparable or superior performance to state-of-the-art methods, with lower computational complexity. These results highlight the effectiveness of explicitly addressing noise through diffusion modeling, improving the reliability and generalization of non-contact physiological measurement systems.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Log in via an institution

Subscribe and save

Springer+
from $39.99 /Month
  • Receive 10 units per month
  • Download 1 article/chapter for 1 unit
  • Get selected eBooks for 7 units
  • Cancel anytime
View plans

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2

Similar content being viewed by others

Heart Rate Estimation Method Based on Frame Difference Fusion and Uncertainty Aware Perception Network

Chapter © 2024

An effective cross-scenario remote heart rate estimation network based on global–local information and video transformer

Article 19 March 2024

Research on Robust Non-contact Heart Rate Detection Methods Resistant to Head Movements and Illumination Variations

Chapter © 2026

Explore related subjects

Discover the latest articles, books and news in related subjects, suggested using machine learning.
  • Biophysical Models
  • Applications of Brownian Motion and Diffusion Theory
  • Diffusion Tensor Imaging
  • Biophysical Methods
  • Diffusion Process
  • Brownian Motion
  • Image Processing Techniques for Enhanced Visual Quality

References

  1. Sun Y, Thakor N. Photoplethysmography revisited: from contact to noncontact, from point to imaging. IEEE Trans Biomed Eng. 2016;63(3):463–77. https://doi.org/10.1109/TBME.2015.2476337.

    Article  Google Scholar 

  2. Gilgen-Ammann R, Schweizer T, Wyss T. RR interval signal quality of a heart rate monitor and an ECG Holter at rest and during exercise. Eur J Appl Physiol. 2019;119(7):1525–32. https://doi.org/10.1007/s00421-019-04142-5.

    Article  Google Scholar 

  3. McDuff D. Camera measurement of physiological vital signs. ACM Comput Surv. 2023;55(9):176:1-176:40. https://doi.org/10.1145/3558518.

    Article  Google Scholar 

  4. Poh MZ, McDuff DJ, Picard RW. Non-contact, automated cardiac pulse measurements using video imaging and blind source separation. Opt Express. 2010;18(10):10762–74. https://doi.org/10.1364/OE.18.010762.

    Article  Google Scholar 

  5. de Haan G, Jeanne V. Robust pulse rate from chrominance-based rPPG. IEEE Trans Biomed Eng. 2013;60(10):2878–86. https://doi.org/10.1109/TBME.2013.2266196.

    Article  Google Scholar 

  6. Yu Z, Li X, Zhao G. Facial-video-based physiological signal measurement: recent advances and affective applications. IEEE Signal Process Mag. 2021;38(6):50–8. https://doi.org/10.1109/MSP.2021.3106285.

    Article  Google Scholar 

  7. Chen W, McDuff D. DeepPhys: video-based physiological measurement using convolutional attention networks. In: Computer vision—ECCV 2018: 15th European conference, Munich, Germany, September 8-14, 2018, Proceedings, Part II. Berlin, Heidelberg: Springer; 2018. p. 356–373. https://doi.org/10.1007/978-3-030-01216-8_22.

  8. Ni A, Azarang A, Kehtarnavaz N. A review of deep learning-based contactless heart rate measurement methods. Sensors. 2021;21(11):3719. https://doi.org/10.3390/s21113719.

    Article  Google Scholar 

  9. Lu H, Han H, Zhou SK. Dual-GAN: Joint BVP and noise modeling for remote physiological measurement. In: 2021 IEEE/CVF conference on computer vision and pattern recognition (CVPR); 2021. p. 12399–12408.

  10. Ho J, Jain A, Abbeel P. Denoising diffusion probabilistic models. In: Proceedings of the 34th international conference on neural information processing systems. NIPS’20. Red Hook, NY, USA: Curran Associates Inc.; 2020. p. 6840–6851.

  11. Niu X, Han H, Shan S, Chen X. VIPL-HR: a multi-modal database for pulse estimation from less-constrained face video. In: Jawahar CV, Li H, Mori G, Schindler K, editors. Computer vision—ACCV 2018. Lecture notes in computer science. Cham: Springer; 2019. p. 562–76.

    Google Scholar 

  12. Stricker R, Müller S, Gross HM. Non-contact video-based pulse rate measurement on a mobile service robot. In: The 23rd IEEE international symposium on robot and human interactive communication; 2014. p. 1056–1062. https://ieeexplore.ieee.org/document/6926392?denied=.

  13. Yu Z, Shen Y, Shi J, Zhao H, Torr P, Zhao G. PhysFormer: facial video-based physiological measurement with temporal difference transformer. In: 2022 IEEE/CVF conference on computer vision and pattern recognition (CVPR); 2022. p. 4176–4186.

  14. Wang W, den Brinker AC, Stuijk S, de Haan G. Algorithmic principles of remote PPG. IEEE Trans Biomed Eng. 2017;64(7):1479–91. https://doi.org/10.1109/TBME.2016.2609282.

    Article  Google Scholar 

  15. Haan Gd, Leest Av. Improved motion robustness of remote-PPG by using the blood volume pulse signature. Physiol Meas. 2014;35(9):1913. https://doi.org/10.1088/0967-3334/35/9/1913.

    Article  Google Scholar 

  16. Balakrishnan G, Durand F, Guttag J. Detecting pulse from head motions in video. In: 2013 IEEE conference on computer vision and pattern recognition; 2013. p. 3430–3437. https://ieeexplore.ieee.org/document/6619284.

  17. Yu Z, Li X, Zhao G. Remote photoplethysmograph signal measurement from facial videos using spatio-temporal networks. In: 30th British machine vision conference 2019, BMVC 2019, Cardiff, UK, September 9-12, 2019. BMVA Press; 2019. p. 277. https://bmvc2019.org/wp-content/uploads/papers/0186-paper.pdf.

  18. Yu Z, Shen Y, Shi J, Zhao H, Cui Y, Zhang J, et al. Physformer++: Facial video-based physiological measurement with slowfast temporal difference transformer. Int J Comput Vis. 2023;131(6):1307–30.

    Article  Google Scholar 

  19. Luo C, Xie Y, Yu Z. PhysMamba: efficient remote physiological measurement with SlowFast temporal difference mamba. In: Chinese conference on biometric recognition. Springer; 2024. p. 248–259.

  20. Yu Z, Li X, Zhao G. Remote photoplethysmograph signal measurement from facial videos using spatio-temporal networks. In: 30th British machine visison conference: BMVC 2019. 9th-12th September 2019, Cardiff, UK. The British Machine Vision Conference (BMVC); 2019.

  21. Goodfellow IJ, Pouget-Abadie J, Mirza M, Xu B, Warde-Farley D, Ozair S, et al. Generative adversarial nets. In: Proceedings of the 27th international conference on neural information processing systems - Volume 2. NIPS’14. Cambridge, MA, USA: MIT Press; 2014. p. 2672–2680.

  22. Song R, Chen H, Cheng J, Li C, Liu Y, Chen X. PulseGAN: learning to generate realistic pulse waveforms in remote photoplethysmography. IEEE J Biomed Health Inform. 2021;25(5):1373–84. https://doi.org/10.1109/JBHI.2021.3051176.

    Article  Google Scholar 

  23. Sohl-Dickstein J, Weiss E, Maheswaranathan N, Ganguli S. Deep unsupervised learning using nonequilibrium thermodynamics. In: Proceedings of the 32nd international conference on machine learning. PMLR; 2015. p. 2256–2265. https://proceedings.mlr.press/v37/sohl-dickstein15.html.

  24. Chen S, Wong KL, Chin JW, Chan TT, So RH. DiffPhys: enhancing signal-to-noise ratio in remote photoplethysmography signal using a diffusion model approach. Bioengineering. 2024;11(8):743.

    Article  Google Scholar 

  25. Niu X, Shan S, Han H, Chen X. RhythmNet: end-to-end heart rate estimation from face via spatial-temporal representation. IEEE Trans Image Process. 2020;29:2409–23. https://doi.org/10.1109/TIP.2019.2947204.

    Article  Google Scholar 

  26. Verkruysse W, Svaasand LO, Nelson JS. Remote plethysmographic imaging using ambient light. Opt Express. 2008;16(26):21434–45. https://doi.org/10.1364/OE.16.021434.

    Article  Google Scholar 

  27. Kazemi V, Sullivan J. One millisecond face alignment with an ensemble of regression trees. In: 2014 IEEE conference on computer vision and pattern recognition; 2014. p. 1867–1874. https://ieeexplore.ieee.org/document/6909637.

  28. Bobbia S, Macwan R, Benezeth Y, Mansouri A, Dubois J. Unsupervised skin tissue segmentation for remote photoplethysmography. Pattern Recognit Lett. 2019;124:82–90. https://doi.org/10.1016/j.patrec.2017.10.017.

    Article  Google Scholar 

  29. Lee E, Chen E, Lee CY. Meta-rPPG: remote heart rate estimation using a transductive meta-learner. In: Vedaldi A, Bischof H, Brox T, Frahm JM, editors. Computer vision—ECCV 2020. Lecture notes in computer science, vol. 12372. Cham: Springer; 2020. p. 392–409.

    Google Scholar 

  30. Tulyakov S, Alameda-Pineda X, Ricci E, Yin L, Cohn JF, Sebe N. Self-adaptive matrix completion for heart rate estimation from face videos under realistic conditions. In: 2016 IEEE conference on computer vision and pattern recognition (CVPR); 2016. p. 2396–2404. https://ieeexplore.ieee.org/document/7780632.

  31. Carreira J, Zisserman A. Quo Vadis, action recognition? A new model and the kinetics dataset. In: 2017 IEEE conference on computer vision and pattern recognition (CVPR). Honolulu, HI: IEEE; 2017. p. 4724–4733. http://ieeexplore.ieee.org/document/8099985/.

  32. Niu X, Han H, Shan S, Chen X. SynRhythm: learning a deep heart rate estimator from general to specific. In: 2018 24th international conference on pattern recognition (ICPR); 2018. p. 3580–3585. https://ieeexplore.ieee.org/document/8546321.

  33. Liu X, Hill B, Jiang Z, Patel S, McDuff D. EfficientPhys: enabling simple, fast and accurate camera-based cardiac measurement. In: 2023 IEEE/CVF winter conference on applications of computer vision (WACV). Waikoloa, HI, USA: IEEE; 2023. p. 4997–5006. https://ieeexplore.ieee.org/document/10030453/.

Download references

Funding

This work was supported in part by Institute of Information & communications Technology Planning & Evaluation (IITP) grant funded by the Korea government(MSIT) (No.RS-2024-00422599, Development of the Personalized Just-in-Time Craving Management System for Substance Use Disorders) and in part by the IITP(Institute of Information & Coummunications Technology Planning & Evaluation)-ITRC(Information Technology Research Center) grant funded by the Korea government(Ministry of Science and ICT)(IITP-2025-RS-2022-00156225).

Author information

Authors and Affiliations

  1. Department of Electrical and Computer Engineering, Seoul National University, Seoul, 08826, Republic of Korea

    Yong-Hoon Jeong

  2. Department of Electronics and Communications Engineering, Kwangwoon University, Seoul, 01897, Republic of Korea

    Young-Seok Choi

Authors
  1. Yong-Hoon Jeong
    View author publications

    Search author on:PubMed Google Scholar

  2. Young-Seok Choi
    View author publications

    Search author on:PubMed Google Scholar

Contributions

All authors contributed to the study design, writing draft, review, and editing.

Corresponding author

Correspondence to Young-Seok Choi.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Ethics approval

This article does not contain any studies with human participants or animals performed by any of the authors.

Consent to participate

This research did not involve human participants, and as such, consent to participate is not required.

Consent for publication

This manuscript does not contain any individual person’s data in any form.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Cite this article

Jeong, YH., Choi, YS. Diffusion-Phys: noise-robust heart rate estimation from facial videos via diffusion models. Biomed. Eng. Lett. 15, 575–585 (2025). https://doi.org/10.1007/s13534-025-00472-w

Download citation

  • Received: 27 December 2024

  • Revised: 11 March 2025

  • Accepted: 21 March 2025

  • Published: 09 April 2025

  • Version of record: 09 April 2025

  • Issue date: May 2025

  • DOI: https://doi.org/10.1007/s13534-025-00472-w

Share this article

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

Keywords

  • rPPG
  • Diffusion model
  • HR estimation
  • Non-contact physiological measurement

Profiles

  1. Young-Seok Choi View author profile
You are visitor 01402775 — GeezerVison does not store the pages you look up.
Best viewed with Netscape Navigator 4.7 or Internet Explorer 6 at 800×600. No cookies required.