GeezerVison is showing raidionics.github.io — Raidionics — CNS tumor segmentation and standardized reporting
Skip to content
Open-source · SINTEF Medical Image Analysis
Segment CNS tumors. Generate the report. In one workflow.
Raidionics automatically segments central nervous system tumors from MRI and produces a standardized clinical report — as a desktop app or a 3D Slicer plugin.
4 CNS tumor types
IDH-wildtype and IDH-mutant glioma Meningioma · Metastasis
16 partner hospitals
Contributing training data across Europe and the United States
3 operating systems
Windows · macOS · Linux Runs entirely on your machine
16+ peer-reviewed papers
Core and related research published in full
What it does
Tumor segmentation and standardized reporting, without the manual work
Built for neurosurgical and radiological research teams working with pre- and post-operative MRI, where volumes and locations are measured by hand today.
Segmentation
Voxel-wise tumor masks from a single click, trained with an Attention U-Net architecture on partner-hospital data.
Tumors
IDH-mutant and IDH-wildtype gliomas, meningiomas, metastases
Structures
Enhancing tissue, tumor core, FLAIR hyperintensity, resection cavity
Standardized reporting
Every mask becomes the same set of numbers, so cases and cohorts can be compared directly.
Features
Volume, diameters, multifocality, laterality
Atlases
Cortical: MNI, Harvard-Oxford, Schaefer · subcortical: BCB
Surgical reporting
Pre- and post-operative scans are reported together, quantifying what the surgery achieved.
Volumes
Brain and tumor volumes before and after surgery
Grading
Extent of resection and surgical grading per RANO 2.0
How it works
One pipeline, from scan to report
Four steps, fully automatic. The desktop app and the 3D Slicer plugin are front ends over the same open-source backend libraries.
01
MRI input
Pre- or post-operative scans, as raw DICOM or volume formats such as NIfTI.
02
Segmentation
In-house trained models outline the tumor compartments: contrast-enhancing, surrounding non-enhancing, FLAIR hyperintensity.
03
Feature computation
Volumes, diameters, laterality and cortical/subcortical profiles, mapped onto reference atlases.
04
Standardized report
A structured clinical report ready for review, following the EANO/RANO 2.0 guidelines.
Runs locally
Inference happens on your own machine through a graphical interface. No data leaves it, and no internet connection is needed to process a patient.
Scriptable backends
The segmentation and reporting libraries are usable on their own via Python, the command line, or Docker — for batch studies and reproducible pipelines.
Open source
BSD-2-Clause licensed, developed in the open, with trained models released alongside the peer-reviewed papers describing them.
See it in action
Two ways to run Raidionics
Use it as a stand-alone desktop app, or inside 3D Slicer if that's already part of your workflow.
Stand-alone Raidionics
A self-contained desktop app — install it and go, no other software required.
View on GitHub →
3D Slicer plugin
Runs the same segmentation and reporting pipeline inside 3D Slicer.
View on GitHub →
Model training data provided by partner hospitals across Europe and the US
St. Olavs hospital Trondheim, Norway
Sahlgrenska University Hospital Gothenburg, Sweden
Brigham and Women's Hospital Boston, United States
Oslo University Hospital Oslo, Norway
Amsterdam University Medical Centers Amsterdam, The Netherlands
Twee Steden Hospital Tilburg, Netherlands
Humanitas Research Hospital Milan, Italy
UCSF Medical Center San Francisco, United States
Medical University of Vienna Vienna, Austria
Northwest Clinics Alkmaar, Netherlands
Medical Center Haaglanden The Hague, The Netherlands
Hôpital Lariboisière Paris, France
University Medical Center Utrecht Utrecht, The Netherlands
Isala Hospital Zwolle, The Netherlands
University Medical Center Groningen Groningen, The Netherlands
The Netherlands Cancer Institute Amsterdam, The Netherlands
Get the software
Download Raidionics
Free installers for Windows, macOS, and Ubuntu Linux. Prefer 3D Slicer? Use the plugin instead.
Latest release · v1.3.2
Prefer 3D Slicer? Get the Raidionics-Slicer plugin instead.
Research software. Raidionics is intended for research use. It is not a certified medical device, it has no CE mark or FDA clearance, and its outputs must not be used as the sole basis for diagnosis or treatment decisions. All results should be reviewed by a qualified clinician.
Research
Publications
The methods behind Raidionics, and related clinical research using the platform.
How to cite Raidionics
If Raidionics contributed to your work, please cite the software paper. Reporting the version you used (visible in the app's About dialog) helps others reproduce your results.
@article{bouget2023raidionics,
title = {Raidionics: an open software for pre- and postoperative
central nervous system tumor segmentation and standardized reporting},
author = {Bouget, David and Alsinan, Demah and Gaitan, Valeria and
Helland, Ragnhild Holden and Solheim, Ole and Reinertsen, Ingerid},
journal = {Scientific Reports},
volume = {13},
number = {1},
pages = {15570},
year = {2023},
doi = {10.1038/s41598-023-42048-7}
}
Who's behind it
Team
Built by SINTEF Medical Image Analysis with clinical partners at St. Olavs Hospital and NTNU.
|