Controls Atlona AV switchers, matrix switchers, scalers and amplifiers over the network: input selection and routing, volume and mute, display output, HDCP, and device status. The Atlona range is now part of Hall Technologies.
Atlona products use three control protocols. This adapter is designed to cover all three with one state tree, so scripts and visualisations work the same way across models:
| Protocol | Connection | Models |
|---|---|---|
| Colon/JSON | JSON-RPC WebSocket (ws://<ip>/API) or telnet |
AT-UHD-SW-510W (supported), AT-OME-MS52W (planned) |
| ASCII | Telnet | Omega, UHD-PRO3, HDR-H2H, Opus, Juno, UHD-SW, HDR-SW, CLSO, HDVS, CAT, GAIN (planned) |
| JSON-RPC 2.0 | WebSocket | AT-PRO5-MX810, AT-OME-CS31-SA, AT-USB-EX350 (planned) |
Version 0.1.0. The AT-UHD-SW-510W is fully supported. The other models follow in stages.
| Model | Status | Tested on hardware |
|---|---|---|
| AT-UHD-SW-510W | Supported | Yes. Firmware 2.9.8, over both the WebSocket and telnet: status, volume, both mutes, display output, HDCP, input switching, matrix mode and routing were each changed and restored on a real unit. Audio source and reboot are not verified |
| AT-OME-MS52W | Planned | No |
| Omega (PS62, MS42, SW32), UHD-SW / HDR-SW, GAIN-60/120 | Planned next | No |
| UHD-PRO3, HDR-H2H, Opus, Juno, CLSO, HDVS, CAT, HDR-M2C, DISP-CTRL | Planned | No |
| AT-PRO5-MX810, AT-OME-CS31-SA | Planned | No |
Models not tested on hardware are built from Atlona's published API documents and are marked as such. Owners who can test a model are very welcome to report in the issue tracker. AV-over-IP (OmniStream), cameras and Velocity panels are not in scope.
- Node.js 22 or newer
- js-controller 6.0.11 or newer, admin 7.6.20 or newer
- Network control enabled on the device (the default). If the device restricts access by IP address, the ioBroker host must be allowed
| Option | Default | Description |
|---|---|---|
| Device address | IP address or host name of the device | |
| Device model | AT-UHD-SW-510W | The connected model |
| Connection | Automatic | Automatic uses the WebSocket where the model has one (AT-UHD-SW-510W), otherwise telnet. Telnet or WebSocket can also be chosen explicitly |
| Telnet port | 23 |
TCP port of the telnet control interface |
| WebSocket port | 80 |
HTTP port of the JSON-RPC WebSocket (ws://<ip>:<port>/API) |
| Username | admin |
Sent only if the device asks for a telnet login |
| Password | (Atlona default) | Sent only if the device asks for a telnet login. Stored encrypted |
| Polling interval | 30000 |
How often the full status is read, in ms (15000 to 3600000) |
Add one instance per device.
How the adapter talks to the device:
- It keeps one connection open, sends at most one command every 500 ms, and matches every reply to the command that caused it.
- At startup it only reads the device. It never changes an input, the volume or the power by itself.
- If the connection drops, or the device stops answering,
info.connectionturns false and the adapter reconnects in the background (5 s, doubling up to 60 s). - Atlona devices allow only a few telnet sessions at a time (the AT-UHD-SW-510W only one). The AT-UHD-SW-510W's WebSocket accepts several clients, answers faster and reports routing changes immediately, so it is used by default.
Every model creates only the states it supports. Inputs and outputs are numbered from 1, matching the labels on the device.
| State | Description |
|---|---|
info.connection |
The connection to the device is open and answering |
info.model, info.firmware |
Model and firmware version reported by the device |
info.temperature |
Internal temperature in °C (models that report it) |
control.source |
Active input (switchers) |
control.volume, control.mute |
Volume and mute (models with one audio output) |
control.power |
Power (models with power control) |
inputs.<n>.signal |
A signal is present on input <n> |
outputs.<n>.source |
Input routed to output <n> (matrix switchers) |
outputs.<n>.volume, outputs.<n>.mute |
Per-output volume and mute |
Writes are checked before anything is sent: a value out of range, a blank value or a wrong type is refused
with a warning in the log; polled states show the device's real value again at the next poll. Buttons act
only when true is written.
Inputs: 1 USB-C, 2 DisplayPort, 3 HDMI 1, 4 HDMI 2, 5 Wireless (BYOD). Outputs: 1 HDBaseT, 2 HDMI.
| State | Description |
|---|---|
control.source |
Active input (1 to 5) |
control.volume |
Volume, -80 to 0 dB |
control.muteHdmi, control.muteAnalog |
Mute the HDMI or the analog audio output |
control.display |
Display output on; off mutes audio and video |
control.audioSource |
Write digital (audio from the video input) or analog (analog audio in) to set the active input's audio source. Telnet connection only, not available while the wireless input is active, and not read back (see known limitations) |
control.matrixMode |
0 off, 1 matrix, 2 matrix with static route |
outputs.<n>.source |
Input shown on output <n>. Settable only while matrix mode is on |
inputs.<n>.signal |
A signal is present on input <n> |
inputs.<n>.hdcp |
HDCP enabled on wired input <n> (1 to 4) |
commands.reboot |
Reboot the device |
commands.byodKick |
Disconnect all wireless (BYOD) clients |
Routes and input signals update immediately when the device reports a change; the rest is read at the polling interval.
Set the instance's log level to debug to see every command and reply.
| Log message | Cause and fix |
|---|---|
Device closed the connection straight away |
The device refuses the connection, usually because of an IP whitelist, or telnet is disabled in the device's web interface. Allow the ioBroker host |
Full Connections |
All telnet sessions are in use by other clients. Close them, or use the WebSocket connection |
Login rejected: check username and password |
The device asks for a telnet login and the credentials are wrong. Use the device's web interface credentials |
Cannot connect to … |
The device is unreachable. The adapter keeps retrying in the background and logs the recovery |
Cannot set … : … Is matrix mode on? |
Output routes can be changed only in matrix mode. Set control.matrixMode to 1 first |
- Audio source (AT-UHD-SW-510W): the device accepts the command, but its
Audio:GetSourcequery did not reflect the change in testing, so the setting is not read back. Its WebSocket parameters are undocumented, so it is available over telnet only. - Wireless input signal (AT-UHD-SW-510W, WebSocket): the device's status query reports the wireless input as active with no client connected, so this one signal is taken from the device's change notifications only.
- Reboot has not been tested on hardware.
- AT-UHD-SW-510W support: input, volume, mutes, display, HDCP, matrix mode and routing, over the WebSocket (default) or telnet
- Initial release
MIT License
Copyright (c) 2026 Alan Paris [email protected]