GeezerVison is showing github.com — GitHub - BetterTIA/watch: Read-only MCP server for live values from a running TIA Portal V21 (Openness): PLC online state, data block snapshots, screenshots of monitored editors.

BranchesTags
Open more actions menu

Latest commit

 

History

15 Commits
15 Commits

Folders and files

NameName
Last commit message
Last commit date
src/BtiaWatch
src/BtiaWatch
 
 
tests/BtiaWatch.Test
tests/BtiaWatch.Test
 
 
.gitignore
.gitignore
 
 
BtiaWatch.slnx
BtiaWatch.slnx
 
 
CHANGELOG.md
CHANGELOG.md
 
 
LICENSE
LICENSE
 
 
README.md
README.md
 
 

Repository files navigation

BetterTIA Watch

Read-only live values from a running TIA Portal V21, for AI agents. An MCP server (stdio) that lets an agent check the online state of a PLC, read the actual values of data blocks and look at a monitored watch table, tag table or block - without someone taking screenshots by hand.

It is one of the four tools of the BetterTIA set:

Tool Role
reader reads a TIA Portal project through Openness and exports it to a folder (read-only MCP server)
writer writes to a TIA Portal project through Openness (MCP server)
editor draws a network from the export, lets you compose a change and tracks it until it is in the project
watch (this repository) reads live values from the running PLC through TIA Portal (read-only MCP server)

All four are developed, used and tested only with TIA Portal V21.

Status: early (0.1.x). The tools are tested against a fake TIA Portal and were checked once against a real PLC with TIA Portal V21 (see below); what only the fake covers is marked there.

Tools

Tool What it does Source
watch_online Online state of a PLC (OnlineProvider.State); action goOnline connects to an allowed target address over a named pcInterface (or adopts a connection that is already online), goOffline disconnects Openness
watch_db Actual values of one or more data blocks: ValueService.CreateSnapshot(), then InterfaceSnapshot.Export() with read-only attributes; returns the snapshot time and one path = value (type) line per member (section headers left out; at most maxRows rows per block, default 500, otherwise truncated: true and the number of rows left out; the answer ends with projectMarkedModified). Technology objects (PID_Temp, PID_Compact, ...) are found by name, but Openness V21 gives no actual values for them (Interface is not supported on TechnologicalInstanceDB): the call says so and points to a watch table with watch_screen; members keeps only the members at or below the given paths (e.g. State,Config.Input). Requires the PLC to be online Openness
watch_screen Opens a watch table, tag table or block (ShowInEditor()), switches monitoring on when allowed (Monitor button through MSAA, Ctrl+T "Monitor all" as fallback), and returns a PNG capture of the TIA Portal window (PrintWindow) as MCP image content Openness + Win32

Common parameters: plc (PLC software name, optional when the project has one PLC) and portalId (process id, optional when one TIA Portal is running). The server attaches to a running TIA Portal; it never starts one.

Configuration

Environment variable Meaning
BTIA_WATCH_ALLOWED_TARGETS Comma-separated IP addresses watch_online goOnline may connect to, e.g. 192.0.2.10,192.0.2.11. Empty or unset: goOnline is refused and the tool only reports the state.

Safety rules

  • Going online only to an allowed address. goOnline calls OnlineProvider.GoOnline(ConfigurationAddress) with the given target on the given PG/PC interface (ConnectionConfiguration.Modes -> PcInterfaces -> Addresses). The parameterless GoOnline(), which connects over the last used interface to the address stored in the project, is never called; a test scans the sources for it.
  • Monitor button first, Ctrl+T only as fallback. Monitoring is switched on by pressing the editor's "Monitor" toolbar button through MSAA (accDoDefaultAction): TIA Portal is not brought to the front and no keys are sent. Ctrl+T is sent only when no button could be pressed or monitoring still reads as off after the press (not when the state is unreadable after a press: Ctrl+T toggles). The result says which path was used. Not yet checked against TIA Portal.
  • Ctrl+T only over a connection this server opened or adopted. In an offline editor Ctrl+T makes TIA Portal open its "Go online" dialog and connect by itself over the last used interface. watch_screen therefore sends Ctrl+T only when OnlineProvider.State is Online and the connection was opened by watch_online goOnline of this server process (an adopted connection counts, see below). Otherwise it captures the editor without the shortcut and says why. The Monitor button is kept to the same rule. sendShortcut=false presses and sends nothing.
  • Ctrl+T is a toggle. Before sending it, the server reads the pressed state of the editor's "Monitor" toolbar button (MSAA) and sends Ctrl+T only when monitoring is off; afterwards it reads the state again. When the button cannot be read, Ctrl+T is sent once with a warning. One call sends it at most once.
  • Adopted connections. If the PLC is already online (for example from an earlier server process), goOnline still checks target against the allowed list and then adopts the connection. Openness does not expose the address of an open connection, so the adopted connection is not compared with target.
  • Foreign dialogs. If a new window of the TIA Portal process appears after the button press or Ctrl+T, it is closed with Esc and the call fails.
  • Focus. A minimized TIA Portal window is restored without activation before the capture; only for the Ctrl+T fallback TIA Portal is brought to the front (no Alt key: it opens the menu bar) and the previous foreground window gets the focus back after the capture. Keys are only sent when TIA Portal really is the foreground window.
  • No empty snapshots. CreateSnapshot() offline returns without error and leaves the snapshot empty, so watch_db refuses to run unless the PLC is online.

Read-only by design

  • Nothing writes values to the PLC. The value-loading methods of ValueService are not called anywhere in the code, and no parameter can reach them. A test scans the sources for them.
  • Fail-safe data blocks are refused by watch_db (tested only against the fake: the refusal sits in the Openness layer, which the tests do not reach).
  • Side effects that remain: watch_db stores the snapshot in the offline project, so TIA Portal shows the project as changed (the server never saves it, and Openness has no way to undo it; the answer reports projectMarkedModified); goOnline creates the given address on the PG/PC interface when it is not there yet, which also changes the offline project; watch_screen opens an editor and, only on the Ctrl+T fallback, briefly brings TIA Portal to the front.

Verified so far

Checked against TIA Portal V21 with a real PLC: goOnline over a named PG/PC interface, adopting an existing connection, watch_db values of global DBs with structures and arrays, watch_screen on a watch table, a tag table and a LAD block (monitoring state read, Ctrl+T sent only when off), goOffline. Call the tools one after another: two concurrent watch_screen calls fight over the active editor.

Not yet checked: instance DBs of GRAPH blocks, very large DBs (the maxRows cut is tested only against the fake), projectMarkedModified (reads Project.IsModified; fake only), floating editors (found by window title; fake only), other monitors and DPI scaling.

Requirements

  • Windows, .NET Framework 4.8
  • Siemens TIA Portal V21 with Openness, running with a project open
  • The user is a member of the Windows group Siemens TIA Openness
  • User environment variable TiaPortalLocation pointing to the TIA Portal V21 installation folder

Build and test

dotnet build BtiaWatch.slnx -c Release
dotnet test BtiaWatch.slnx -c Release

The tests need neither TIA Portal nor a PLC: the tools run against a fake IWatchPortal, and the window capture is tested on a window of the test process.

Register in Claude Code

A running server locks its .exe, so build a copy per version and point the client at that copy, e.g. dotnet build src\BtiaWatch -c Release -o dist\0.1.5 (dist/ is ignored by git). Add the server to .mcp.json under the key BTIA_Watch:

"BTIA_Watch": {
  "type": "stdio",
  "command": "<repository>\\dist\\0.1.5\\BtiaWatch.exe",
  "args": [],
  "env": { "BTIA_WATCH_ALLOWED_TARGETS": "192.0.2.10" }
}

License

MIT, see LICENSE.

About

Read-only MCP server for live values from a running TIA Portal V21 (Openness): PLC online state, data block snapshots, screenshots of monitored editors.

Topics

mcp-serverplcplc-monitoringsiemenssiemens-plcsiemens-s7siemens-tiatia-portaltia-portal-opennesstia-portal-v21

Resources

Readme
MIT license
Activity
Custom properties

Stars

1 star

Watchers

0 watching

Forks

0 forks
Report repository

Releases

Packages

Contributors

Languages

You are visitor 01402775 — GeezerVison does not store the pages you look up.
Best viewed with Netscape Navigator 4.7 or Internet Explorer 6 at 800×600. No cookies required.