GV

GeezerVison

The World Wide Web, restored to 800 pixels of glory.

Home|About|Gaming cabinet|Archives|How it works|Starter sites

On this site

  • Sign in
  • ActionsCI/CD and automation
  • CodespacesCloud development environments
  • All Features
  • Documentation
  • Training
  • Certifications
  • Build with Copilot
  • Customize Copilot
  • Integrations
  • Trending repos
  • GitHub Sponsors
  • Developer articles
  • Enterprises

This view

  • Original page
  • New address

GeezerVison is showing github.com — GitHub - GiovanniAsantos/projeto2-cnn-chest-xray-pneumonia: CNN pipeline for pneumonia detection on chest X-rays. Infnet MBA.

BranchesTags
Open more actions menu

Latest commit

 

History

4 Commits
4 Commits

Folders and files

NameName
Last commit message
Last commit date
checkpoints
checkpoints
 
 
imbalance_comparison
imbalance_comparison
 
 
notebooks
notebooks
 
 
optuna_search
optuna_search
 
 
resnet_transfer_comparison
resnet_transfer_comparison
 
 
runs
runs
 
 
src
src
 
 
weight_init_comparison
weight_init_comparison
 
 
.gitignore
.gitignore
 
 
README.md
README.md
 
 
requirements.txt
requirements.txt
 
 

Repository files navigation

Projeto 2 — Arquitetura Especializada: CNN para Triagem de Pneumonia em Raios-X

Dataset

PneumoniaMNIST (MedMNIST v2) — mesma fonte clínica do Kaggle chest-xray-pneumonia (Kermany et al., raio-X pediátrico), já re-empacotada com splits oficiais estratificados e resolução configurável: https://medmnist.com/

  • Classificação binária normal vs pneumonia, grayscale, carregada em 28×28 no pipeline principal (a CNN customizada) — resolução nativa do MedMNIST, suficiente porque os sinais diagnósticos relevantes (opacidade difusa, consolidação) são padrões grandes, não detalhe fino. A comparação extra com ResNet18 pré-treinado (seção separada, não obrigatória) usa 128×128, exigido pelo backbone ImageNet.
  • Splits oficiais: treino 4.708 (1.214 normal / 3.494 pneumonia), validação 524, teste 624 (234 normal / 390 pneumonia — idêntico ao split de teste do Kaggle original)
  • Baixado automaticamente via pip install medmnist (sem credencial necessária) na primeira execução do notebook/scripts, cacheado em data/

Por que CNN

Raio-X de tórax é imagem 2D onde o diagnóstico depende de padrões espaciais locais (opacidades, consolidações, infiltrados) e de sua distribuição pelos campos pulmonares. Correlação espacial entre pixels vizinhos e invariância a translação (uma opacidade importa onde quer que apareça no pulmão) tornam convolução com pesos compartilhados a escolha estrutural correta — o inductive bias de CNN casa com a natureza do dado, diferente de um MLP (que ignora estrutura 2D) ou de uma RNN (que não tem noção nativa de vizinhança bidimensional).

Estrutura

projeto2-chest-xray-pneumonia/
├── data/                                # cache do medmnist (.npz, gitignored)
├── notebooks/
│   └── cnn_pneumonia.ipynb              # notebook principal do pipeline
├── src/                                 # data.py, model.py, engine.py, metrics.py, utils.py
├── weight_init_comparison/train.py      # ablação opcional (default/xavier/he)
├── imbalance_comparison/train.py        # problema real diagnosticado (class_weight)
├── resnet_transfer_comparison/train.py  # comparação extra (ResNet18 fine-tuning)
├── optuna_search/search.py              # busca leve de hiperparâmetros (12 trials)
├── checkpoints/                         # melhores modelos salvos (.pt, gitignored)
├── runs/                                # logs TensorBoard (gitignored)
└── requirements.txt

Setup

python -m venv venv
./venv/Scripts/activate        # Windows
pip install -r requirements.txt

O dataset é baixado automaticamente (via pacote medmnist) na primeira execução do notebook ou de qualquer script — não precisa de passo manual.

Rodar

python optuna_search/search.py              # gera checkpoints/best_hparams.json
python imbalance_comparison/train.py        # diagnóstico obrigatório
python weight_init_comparison/train.py      # ablação opcional
python resnet_transfer_comparison/train.py  # comparação extra

Depois, execute notebooks/cnn_pneumonia.ipynb do início ao fim (ele reusa os resultados salvos pelos scripts acima) ou rode tensorboard --logdir runs pra visualizar as curvas.

Status

  • Ambiente configurado e verificado (PyTorch, TensorBoard) — CPU-only
  • Dataset carregado com splits oficiais (PneumoniaMNIST)
  • CNN implementada com justificativa de design
  • Pipeline de treinamento (DataLoader, validação por época, checkpoint, LR scheduling)
  • Diagnóstico: gradient norms, class_weight (desbalanceamento), curvas TensorBoard
  • Métricas no teste + baseline não trivial
  • Matriz de confusão interpretada
  • Análise de alternativas arquiteturais (CNN vs LSTM/GRU, ~520 palavras)

Projeto completo — ver RELATORIO.md (relatório técnico local, não versionado) para a análise completa. Pipeline verificado rodando do início ao fim sem erro (notebook + todos os scripts).

About

CNN pipeline for pneumonia detection on chest X-rays. Infnet MBA.

Topics

cnncomputer-visiondeep-learningmedical-imagingpython

Resources

Readme
Activity

Stars

0 stars

Watchers

0 watching

Forks

0 forks
Report repository

Releases

Packages

Contributors

Languages

You are visitor 01402792 — GeezerVison does not store the pages you look up.