Status: foundational research program and computational scaffold. This repository is not a clinical device, does not claim to have solved the hard problem, and does not assume in advance that consciousness is physical, nonphysical, emergent, fundamental, dual-aspect, or reducible to any one measurable signal.
The program asks one concrete measurement-science question:
What observations, interventions, mathematical structures, assumptions, and validation standards would justify a scientific claim about consciousness?
A subject has first-person access to their own experience. An external investigator observes reports, behavior, neural activity, physiology, perturbational responses, interventions, and context. Research III makes the inferential bridge between those observations and a declared experiential target explicit rather than hiding it inside one score.
This orientation schematic shows the V16-V55 evidence path as eight linked scientific gates: field organization, source identifiability, resolution, measurement design, finite-sample inference, selection safety, replication, and transportability. Each stage states the failure mode it is designed to expose and keeps the claim ceiling visible. It is an orientation map, not an additional empirical result and not part of the nine foundational architecture-figure count.
For the fastest technical orientation, use these three entry points first:
- Visual Research Guide for the foundational visual record and the V16-V55 evidence architecture.
- Evidence-to-Claim Audit for the exact path from observable evidence to an allowed scientific claim.
- Figure Catalog for the canonical figure inventory and primary audit source for every visual.
- Formal Validation V1-V55 for the executable analytic and synthetic validation record, including the electromagnetic measurement, inverse, resolution, design, finite-sample, selection-safe, and cross-site replication-inference and transportability layers V16-V55.
Then continue with Start Here, Research Questions, Formal Measurement Framework, and the full Documentation Map.
Research III currently exposes nine canonical scientific visuals. They organize the complete measurement program without converting specification into empirical evidence.
The whole-program map separates five declared targets - presence, global state, content, phenomenal structure, and capacity - from the observable channels used to study them. Evidence reaches a claim only through explicit assumptions, identification analysis, validation, and claim discipline.
Audit: Measurement Framework, Assumption Registry, Claim Registry.
A modality can be informative for one target and insufficient for another. The matrix is not a ranking of evidence channels. It is a guard against category errors such as treating failed motor output as proof of absent experience or treating a neural predictor as direct access to subjective feel.
Audit: Measurement Instrument Specification, Failure Modes, Clinical Translation.
The core architecture separates the latent experiential target from report, behavior, neural activity, perturbational response, physiology, context, and intervention. The allowed output keeps uncertainty, assumptions, validation domain, and claim level visible.
Science observes
[ D=(R,B,N,P,A,I,C), ]
but does not directly observe another subject's experience (E). The central identification question is therefore
[ \boxed{ \text{Given }D\text{ and explicit assumptions }\mathcal A, \text{ what can be identified, bounded, predicted, or falsified about }E? } ]
If the evidence and assumptions do not identify a unique answer, the correct output can be an interval, an identification region, competing explanations, or an inconclusive result.
The Consciousness Evidence Profile (CEP) is structured before it is scalar:
(\mathbf v,\mathbf q,\mathbf u,\mathcal A,\mathcal D,\Gamma). ]
Here (s) is the subject or system, (t) is the time window, (\tau) is the declared target, (c) is context, (\mathbf v) is the evidence vector, (\mathbf q) contains quality and interpretability, (\mathbf u) contains uncertainty, (\mathcal A) is the assumption set, (\mathcal D) is the validation domain, and (\Gamma) is the strongest allowed claim level.
Audit: CEP Specification, CEP schema, worked CEP example.
A measurement program must distinguish three valid outcomes:
- point identified: one target value is licensed under the declared assumptions;
- partially identified: a set or interval is licensed, but no unique value is;
- inconclusive / abstain: evidence, quality, assumptions, or validation are insufficient for a stable claim.
Partial identification is a scientific result, not an analytical failure.
Audit: Statistical Validation, Dependence-Robust Partial Identification.
The structural arm uses a four-layer preregistered workflow:
- phenomenal and physical-neural observations;
- independently constructed relational geometries;
- a frozen mapping family evaluated on held-out relations;
- support, rejection, or an inconclusive outcome.
For communicative participants, define phenomenal and physical relational spaces
[ (\mathcal E,d_E), \qquad (\mathcal N,d_N). ]
A candidate mapping (f:\mathcal N\to\mathcal E) can be evaluated with a preregistered held-out distortion statistic. Low distortion can support the declared mapping family. High distortion can reject it. Neither result establishes ontological identity between physical structure and experience.
Audit: Phenomenal Structure Program.
Validation is staged rather than collapsed into one accuracy number. The program moves from report-rich benchmarks through confound separation, transport across altered states, causal perturbation, clinical stress tests, held-out structural prediction, and adversarial theory comparison.
Stronger claims therefore require broader validation, not simply a higher in-sample score.
Audit: Phase 1 Protocol, Experimental Program, Preregistration Template, Roadmap.
Candidate theories are compared by declared commitments and preregistered divergent predictions. Shared support is not the same as a unique theory win. A theory-relative empirical result does not settle ontology.
Audit: Theory Landscape, Falsification Matrix, Literature Map.
The repository uses a conservative M0-M7 ladder:
| Level | Allowed claim |
|---|---|
| M0 | A signal, behavior, or feature differs between declared experimental conditions. |
| M1 | A locked model predicts a validated report or behavioral target out of sample. |
| M2 | The relation generalizes across participants or sites inside a declared domain. |
| M3 | The relation generalizes across distinct consciousness manipulations or states. |
| M4 | The relation survives confound controls and causal perturbation tests. |
| M5 | A multimodal model identifies or bounds a latent experiential target under explicit assumptions. |
| M6 | A preregistered physical structure predicts held-out phenomenal structure. |
| M7 | A candidate theory makes a unique preregistered prediction that survives while relevant rivals fail. |
No rung licenses the statement that qualia have been directly measured.
Audit: Claim Registry, claim schema, worked claim example.
The repository separates targets that are often mixed together:
| Target | Core question | Typical anchors | Common category error |
|---|---|---|---|
| Presence | Is there evidence that any experience is occurring? | report when available, covert command following, state markers, perturbational capacity | treating one failed channel as proof of absence |
| Global state | What multidimensional condition is the system in? | arousal, connectedness, complexity, stability, cognitive availability | compressing all states into one universal level |
| Content | What is being experienced? | trial-level report, decoding, discrimination, structured behavior | confusing stimulus decoding with experience decoding |
| Phenomenal structure | What relations hold among experiences? | similarity, ordering, discriminability, report geometry | assuming matched neural geometry is ontological identity |
| Capacity | Does the system have organization capable of supporting experience? | causal organization, perturbational response, recurrent dynamics | equating capacity with a currently occurring content |
A measure validated for one target cannot automatically be promoted to another.
Current consciousness science contains many useful measurements, but each occupies a different evidential layer.
| Evidence channel | What it can support | What it cannot establish by itself |
|---|---|---|
| First-person report | experienced content when communication is reliable | direct third-person access to qualia |
| Intentional behavior | command following, discrimination, communication | absence of experience when motor output fails |
| Task EEG/fMRI | covert command following and content-related activity | universal absence of consciousness when negative |
| Resting EEG/MEG/fMRI | state-dependent complexity, connectivity, spectra, network organization | a direct reading of subjective feel |
| Electromagnetic organization features | frequency-specific field organization, entropy, rank, phase structure, perturbational dynamics after acquisition controls | consciousness itself, qualia, or a universal field threshold |
| TMS-EEG / PCI family | perturbational capacity for differentiated, integrated cortical responses | a universal metaphysical cutoff |
| Autonomic and ocular signals | covert evidence when overt report is unavailable | a unique consciousness-specific signature across all settings |
| Lesion, stimulation, pharmacology | causal constraints on candidate mechanisms | a complete explanation of why experience exists |
The program therefore emphasizes triangulation, causal intervention, cross-context validation, explicit uncertainty, and theory comparison.
Research III now includes a dedicated Electromagnetic Field Measurement Program for V16-V20, an Electromagnetic Source Identifiability Program for V21-V25, an Electromagnetic Resolution and Information Program for V26-V30, an Electromagnetic Design and Spatial Specificity Program for V31-V35, a Finite-Sample Electromagnetic Inference Program for V36-V40, a Multiplicity and Selection-Safe Electromagnetic Inference Program for V41-V45, a Cross-Site Replication Inference and Stability Program for V46-V50, and a Transportability Across Sensor Systems, Hardware, and States Program for V51-V55.
The measurement model is
[ \mathbf X(t)=\mathcal M(\mathcal F)(t)+\boldsymbol\eta(t), \qquad \mathcal F(\mathbf r,t)={\mathbf E(\mathbf r,t),\mathbf B(\mathbf r,t)}, ]
so a sensor array records a geometry-, hardware-, reference-, and noise-dependent projection of an underlying field rather than an unqualified field essence.
The first electromagnetic feature profile is
[ \Phi_{EM}=(H_f,C_\phi,r_{\mathrm{eff}},H_{SV},\rho_{CM}), ]
covering normalized spectral entropy, frequency-specific sensor-phase concentration, covariance effective rank, normalized singular-value entropy, and common-mode fraction.
V26-V30 quantify covariance-aware residual geometry, inverse resolution leakage, a rank-only lower bound on identity resolution error, Fisher-information loss under correlated noise, exact temporal aliasing, and worst-case pseudoinverse noise amplification. V31-V35 continue into spatial specificity and measurement design through point-spread and cross-talk functions, covariance-aware source distinguishability, Fisher-information sensor design, exact nuisance-subspace information loss, and a robust information bound under bounded model uncertainty. V36-V40 add finite-sample inference through efficient GLS amplitude estimation, inverse-covariance bias, exact Gaussian source-discrimination error, independent-search FWER control, and sandwich-variance calibration under covariance mismatch. These are measurement, design, and inference laws, not consciousness measurements.
V41-V45 then make search multiplicity and data reuse explicit: Bonferroni control remains valid under arbitrary dependence, Holm can gain rejections without weakening strong FWER control, exact sign-flip orbits support finite randomization inference under symmetry, naive same-data selection can destroy nominal coverage, and independent holdout confirmation restores selected-coordinate Type I error under the declared null. These are inference-validity results, not consciousness measurements.
V46-V50 add cross-site replication inference without pretending that synthetic sites are external validation. The layer formalizes inverse-variance pooling, the known-variance Cochran Q law, an exact leave-one-site-out influence identity, Bonferroni partial-conjunction replicability, and the effective site count induced by concentrated inverse-variance weights. These are replication-design and evidence-stability results, not evidence that a consciousness marker has replicated in real cohorts.
V51-V55 add an explicit transportability layer. They prove invariance under fully modeled invertible sensor-coordinate changes, show that rank-reducing projections cannot increase target Fisher information, quantify bias from cross-hardware topography mismatch, expose overlap loss under covariate-shift reweighting through effective sample fraction, and give a sharp total-variation transport budget for bounded outputs. These are analytic transportability laws, not empirical evidence of cross-device or cross-state generalization.
The strongest current conclusions are measurement-science conclusions:
- V17 shows the normalized descriptors are invariant to trivial global gain in the declared deterministic construction;
- V18 gives a constructive counterexample in which channel power is matched to numerical precision while spatial phase organization changes from fully aligned to phase balanced;
- V19 shows that a shared contaminant can create strong apparent sensor-wide phase organization;
- V20 shows that organization can be fully aligned at one frequency and phase balanced at another in the same multichannel signal;
- V21 verifies common-reference invariance of pairwise EEG-like differences;
- V22 constructs distinct source vectors with exactly the same ideal sensor measurement through a lead-field null space;
- V23 makes inverse regularization dependence explicit;
- V24 shows how complementary EEG/MEG-like operators can reduce source ambiguity without guaranteeing uniqueness;
- V25 bounds forward-model perturbation error in sensor space.
- V26 verifies covariance-weighted residual geometry through exact whitening;
- V27 quantifies inverse source-resolution error and off-diagonal leakage;
- V28 gives Fisher-information loss and CRLB growth under common correlated sensor noise;
- V29 constructs exact temporal aliasing between distinct continuous frequencies after sampling;
- V30 makes weakest-singular-direction inverse noise amplification explicit through the pseudoinverse norm;
- V31 separates point-spread from cross-talk behavior through the resolution matrix;
- V32 makes source-topography distinguishability covariance-aware;
- V33 shows that equal sensor count can hide radically different weakest-direction information;
- V34 proves the exact one-target one-nuisance retained-information law (\sin^2\theta);
- V35 proves and attains the exact robust information lower bound under bounded whitened model uncertainty;
- V36 proves GLS unbiasedness and CRLB attainment under known covariance and checks finite-sample variance and coverage with a fixed seed;
- V37 makes inverse-covariance bias from finite Wishart noise estimation explicit;
- V38 converts Mahalanobis source separation into exact equal-prior Gaussian Bayes error;
- V39 gives an exact independent-search family-wise error law and threshold;
- V40 shows how covariance mismatch can make nominal uncertainty materially overconfident.
- V41-V45 make arbitrary-dependence multiplicity control, exact sign-flip inference, post-selection failure, and independent confirmation explicit.
- V46 gives the exact inverse-variance common-effect estimator for the declared synthetic sites.
- V47 checks the known-variance Cochran Q moment law with 50,000 fixed-seed common-effect simulations.
- V48 verifies the exact leave-one-site-out pooled-estimate shift identity for every declared site.
- V49 converts ordered site-level p-values into Bonferroni partial-conjunction replicability p-values.
- V50 shows how one dominant site can reduce four nominal sites to an effective count of about 1.394 and make delete-one variance inflate by about 6.33.
- V51 proves exact sensor-coordinate invariance of the Gaussian GLS amplitude estimate and Fisher information under a consistently transformed invertible measurement system.
- V52 proves that lossy linear projection cannot increase Fisher information for the declared scalar target.
- V53 converts cross-hardware or forward-topography mismatch into an exact amplitude-bias law with a covariance-weighted Cauchy-Schwarz bound.
- V54 shows exact expectation transport under the declared covariate-shift assumptions while making weight concentration and effective sample loss explicit.
- V55 gives a sharp total-variation transport budget for bounded measurement outputs and the canonical construction attains that budget.
These results justify treating electromagnetic dynamics as a rich candidate evidence channel while keeping sensor measurements, reconstructed sources, and experiential targets scientifically distinct. They do not establish an electromagnetic consciousness detector, a universal threshold, or identity between an electromagnetic field and experience.
Candidate mechanisms are classified by role rather than by enthusiasm:
- necessary: removing the condition eliminates the target within the declared scope;
- sufficient: producing the condition produces the target within the declared scope;
- enabling: the condition permits the target but is not enough by itself;
- correlated: the condition tracks the target but may be prerequisite, consequence, or confound.
This prevents a predictive marker from automatically being described as a mechanism, and prevents a mechanism from automatically being described as ontological identity.
A failed test is not automatically evidence of absent experience.
Negative evidence is interpretable only when the assay has demonstrated sensitivity to the declared target, acquisition quality is adequate, the subject or system could in principle produce the measured response, major confounds have been assessed, false-negative behavior is characterized, and the validation domain includes the present use case.
If those conditions fail, the correct output is uninterpretable or inconclusive, not evidence for absence.
This boundary is especially important in severe brain injury, paralysis, sleep, sedation, sensory impairment, and other settings where report or motor behavior can fail independently of experience.
A candidate measurement model is not accepted because it has attractive visualizations or high in-sample accuracy. Confirmatory work requires, as appropriate:
- participant-level and site-level holdout;
- calibration, not only discrimination;
- proper scoring rules;
- uncertainty intervals and identification regions;
- measurement-invariance checks;
- transport to new states and hardware;
- sensitivity to missing data and channel dependence;
- positive and negative controls;
- multiplicity control;
- explicit abstention behavior;
- strong single-channel baselines;
- prospective preregistration of confirmatory endpoints.
See Statistical Validation, Partial Identification, and the Evidence-to-Claim Audit.
Disorders of consciousness are treated as an important validation domain, not as a shortcut to a binary consciousness classifier. Behavioral and brain-based channels both have false-negative pathways, and discordance itself carries information.
The program therefore requires serial behavioral assessment, confound control, repeated testing where appropriate, multimodal evidence, and explicit uncertainty. See Clinical Translation and Ethics.
Nothing in this repository is intended to guide withdrawal of life support, replace specialist clinical evaluation, or function as a diagnostic medical device.
The package contains multiple intentionally small, auditable components:
evidence.pyimplements likelihood-ratio updates under an explicit conditional-independence assumption;partial_identification.pycomputes sharp marginal-only Frechet-Hoeffding bounds when conditional dependence is unknown;profile.pyimplements target-specific CEP records with an explicit inconclusive state and conservative negative-evidence rules;structural_alignment.pyimplements distance matrices, relational alignment, normalized distortion, and permutation testing;electromagnetic_observables.pyimplements physical EM sanity checks and normalized multichannel field-organization descriptors;electromagnetic_simulations.pyimplements deterministic V16-V20 gain, non-identifiability, confound, and frequency-specific stress tests;electromagnetic_inverse.pyimplements reference-invariant sensor relations, lead-field rank/nullity, null-space alternatives, regularized inverse estimates, multimodal stacking, and forward-model perturbation bounds;electromagnetic_inverse_simulations.pyimplements deterministic V21-V25 source-identifiability and forward/inverse stress tests.electromagnetic_resolution.pyimplements covariance weighting, source-resolution diagnostics, Fisher information, sampling alias checks, and pseudoinverse noise-amplification bounds;electromagnetic_resolution_simulations.pyimplements deterministic V26-V30 resolution and information-limit experiments.
These are research scaffolds, not clinical classifiers.
Install and run:
python -m pip install -e ".[dev]"
make checkmake check runs unit tests, repository-policy verification, and Ruff. See Software Guide, Reproducibility, and Repository Policy.
| Object | File | Purpose |
|---|---|---|
| CEP schema | schemas/cep.schema.json | machine-readable evidence-profile contract |
| CEP example | examples/cep_example.json | worked nonclinical profile example |
| Claim schema | schemas/claim.schema.json | machine-readable M0-M7 claim record |
| Claim example | examples/claim_example.json | worked claim with assumptions and nonclaims |
| Repository policy | scripts/verify_repository_policy.py | checks links, schemas, figures, and publication rules |
Supporting guides: Schemas Guide, Examples Guide, Claims Guide, Data Policy.
- Visual Research Guide
- Figure Catalog
- Evidence-to-Claim Audit
- Start Here
- Research Questions
- Glossary
- Epistemic Boundaries
- Formal Measurement Framework
- Assumption Registry
- Failure Modes
- Consciousness Evidence Profile specification
- Claim Registry
- Machine-readable CEP schema
- Worked CEP example
- Machine-readable claim schema
- Worked claim example
- Phase 1 Protocol
- Preregistration Template
- Experimental Program
- Electromagnetic Field Measurement Program
- Electromagnetic Source Identifiability Program
- Electromagnetic Resolution and Information Program
- Formal Validation V1-V50
- Validation Atlas
- Statistical Validation Plan
- Dependence-Robust Partial Identification
- Clinical Translation
- Ethics
- Edge Cases
- five-target taxonomy: presence, global state, content, phenomenal structure, capacity;
- explicit epistemic and ontological boundaries;
- formal latent-target measurement model;
- Consciousness Evidence Profile specification and JSON schema;
- M0-M7 claim ladder;
- machine-readable claim schema and example;
- assumption registry and failure-mode registry;
- preregistration template and cross-state Phase 1 protocol;
- staged experimental roadmap;
- theory landscape and falsification matrix;
- phenomenal-structure framework;
- statistical validation rules and dependence-robust partial-identification bounds;
- clinical translation and ethics boundaries;
- edge-case standards for infants, animals, organoids, and artificial systems;
- computational scaffolds for evidence fusion, partial identification, CEP records, structural alignment, and electromagnetic observables;
- executable formal validation through V30, including electromagnetic invariance, matched-power non-identifiability, common-mode confounding, frequency-specific structure, lead-field null-space non-identifiability, inverse regularization sensitivity, multimodal null-space reduction, forward-model perturbation, covariance whitening, source-resolution leakage, correlated-noise Fisher information, temporal aliasing, and inverse noise-amplification tests;
- nine canonical scientific visuals with a dedicated visual guide and figure catalog;
- unit tests and repository-wide publication checks.
The repository does not yet contain prospective human data that validate a general consciousness measure, a clinically approved instrument, a universal threshold, a demonstrated substrate-independent scalar, direct third-person access to qualia, a validated universal electromagnetic consciousness signature, or a completed adversarial theory tournament.
Those are empirical milestones, not documentation gaps. The Roadmap states the evidence required before they can be claimed.
A mature version of the program could support claims such as:
- a multimodal signature is a calibrated predictor of a declared experiential target across multiple altered states;
- a perturbational response is necessary for a defined class of conscious states within tested conditions;
- a candidate neural architecture is not sufficient because experience dissociates from it;
- a relational geometry of experience is predicted by a physical or causal representation with bounded held-out distortion;
- one theory's unique preregistered prediction survives an adversarial test while relevant competitors fail;
- certain experiential claims remain non-identifiable from available third-person data.
These would be strong scientific results even if the ultimate explanatory question of why experience exists remains open.
It will not claim that:
- consciousness has been proven nonphysical;
- consciousness has been reduced to a conventional state of matter;
- any current scalar metric equals consciousness;
- electromagnetic field strength, power, coherence, entropy, rank, phase concentration, or a particular source reconstruction by itself equals or proves consciousness;
- high complexity alone proves consciousness;
- a failed descriptor proves dualism, idealism, or panpsychism;
- a current AI system is conscious because it behaves intelligently;
- quantum mechanics is required merely because consciousness is mysterious;
- correlation closes the explanatory gap;
- a negative bedside, EEG, fMRI, or perturbational result proves absence of experience without validated sensitivity.
The goal is not to manufacture certainty where science does not yet have it.
The goal is to make consciousness measurement progressively harder to fool: harder to fool with behavior, harder to fool with one biomarker, harder to fool with theory-confirming analysis, harder to fool with hidden assumptions, harder to fool with data leakage, and harder to fool with elegant mathematics that lacks discriminating empirical predictions.
If a broadly valid consciousness measure is possible, this program aims to define the evidence required to earn that claim. If it is not possible under available observations and assumptions, the program should make that limitation scientifically visible.
Transportability audit: V51-V55 Transportability Across Sensor Systems, Hardware, and States.