GeezerVison is showing github.com — GitHub - MouaadO/voltage-stability-analysis: MATLAB voltage-stability application with P–V/Q–V curves, power-factor studies and predictor–corrector continuation for a selected line equivalent.

BranchesTags
Open more actions menu

Latest commit

 

History

6 Commits
6 Commits

Folders and files

NameName
Last commit message
Last commit date
docs
docs
 
 
.gitignore
.gitignore
 
 
README.md
README.md
 
 
fourteen_bus_data.m
fourteen_bus_data.m
 
 
plot_continuation_power_flow.m
plot_continuation_power_flow.m
 
 
plot_pv_qv_curves.m
plot_pv_qv_curves.m
 
 
three_bus_data.m
three_bus_data.m
 
 
voltage_stability_app.m
voltage_stability_app.m
 
 

Repository files navigation

Voltage Stability Analysis

P–V curves · Q–V curves · Predictor–corrector continuation

A MATLAB application for exploring how electrical loading, power factor and reactive-power demand affect receiving-end voltage. The project visualizes the operating branches and critical loading points of a selected line equivalent.

Academic group project at the National Polytechnic School of Algiers.

Project workflow

Study objectives

Analysis Question answered
P–V curves How does receiving-end voltage change as active-power transfer increases?
Q–V curves How does reactive-power demand relate to voltage at a selected active-power level?
Continuation power flow How can the operating curve be followed through its turning region?

The interface selects a network, a line and the study type. The calculations use the selected source voltage and line reactance to form a two-bus equivalent.

Operating principle

For a lossless line equivalent, active and reactive power at the receiving end can be written:

$$P=\frac{V_1V_2}{X}\sin\delta,\qquad Q=\frac{V_1V_2}{X}\cos\delta-\frac{V_2^2}{X}$$

The chosen power factor establishes $Q=P\tan\varphi$. Increasing loading changes both the receiving-end voltage $V_2$ and the angle $\delta$. The high- and low-voltage branches meet at a critical point.

The continuation routine uses a tangent predictor followed by a Newton corrector on an augmented system. Arc-length stepping follows the curve even where active power is no longer a convenient independent parameter.

Report figures

P–V curves and critical loading

P–V curves at different power factors

The curves show how power factor changes the voltage profile and maximum transferable active power in the selected equivalent.

Q–V characteristics

Reactive power versus receiving-end voltage

These plots compare the reactive-power relationship at several active-power levels.

Continuation trajectory

Continuation curve with predictor and corrector steps

Predictor and corrector segments make the numerical process visible. All figures come from the technical report.

Why this implementation

The graphical interface separates case selection from the numerical routines. P–V and Q–V plots provide complementary views of the same voltage/power relationship. The predictor–corrector method adds a geometric view of the solution branch rather than relying only on a sequence of independent load-flow points.

The continuation code starts with a nominal arc-length step of 0.03 and a Newton residual tolerance of $10^{-10}$; it adjusts the step during the trace. These are numerical settings in the supplied implementation.

Run

voltage_stability_app
  1. Select the three-bus or fourteen-bus dataset.
  2. Choose a connected line and an analysis mode.
  3. Enter the requested power factor or loading values.
  4. Inspect the plotted branches, critical points or continuation steps.

Files and tools

File Role
voltage_stability_app.m Graphical interface
plot_pv_qv_curves.m P–V and Q–V calculations
plot_continuation_power_flow.m Tangent prediction and Newton correction
three_bus_data.m, fourteen_bus_data.m Example network data
Report Derivations and worked studies

Tools: MATLAB, numerical linear algebra and MATLAB graphics.

Related projects

Power Flow and Network Analysis · Power System Fault Location with Machine Learning

About

MATLAB voltage-stability application with P–V/Q–V curves, power-factor studies and predictor–corrector continuation for a selected line equivalent.

Topics

continuation-power-flowmatlabnumerical-methodspower-systemsvoltage-stability

Resources

Readme
Activity

Stars

0 stars

Watchers

0 watching

Forks

0 forks
Report repository

Releases

Packages

Contributors

Languages

You are visitor 01402792 — GeezerVison does not store the pages you look up.
Best viewed with Netscape Navigator 4.7 or Internet Explorer 6 at 800×600. No cookies required.