P–V curves · Q–V curves · Predictor–corrector continuation
A MATLAB application for exploring how electrical loading, power factor and reactive-power demand affect receiving-end voltage. The project visualizes the operating branches and critical loading points of a selected line equivalent.
Academic group project at the National Polytechnic School of Algiers.
| Analysis | Question answered |
|---|---|
| P–V curves | How does receiving-end voltage change as active-power transfer increases? |
| Q–V curves | How does reactive-power demand relate to voltage at a selected active-power level? |
| Continuation power flow | How can the operating curve be followed through its turning region? |
The interface selects a network, a line and the study type. The calculations use the selected source voltage and line reactance to form a two-bus equivalent.
For a lossless line equivalent, active and reactive power at the receiving end can be written:
The chosen power factor establishes
The continuation routine uses a tangent predictor followed by a Newton corrector on an augmented system. Arc-length stepping follows the curve even where active power is no longer a convenient independent parameter.
The curves show how power factor changes the voltage profile and maximum transferable active power in the selected equivalent.
These plots compare the reactive-power relationship at several active-power levels.
Predictor and corrector segments make the numerical process visible. All figures come from the technical report.
The graphical interface separates case selection from the numerical routines. P–V and Q–V plots provide complementary views of the same voltage/power relationship. The predictor–corrector method adds a geometric view of the solution branch rather than relying only on a sequence of independent load-flow points.
The continuation code starts with a nominal arc-length step of 0.03 and a Newton residual tolerance of
voltage_stability_app- Select the three-bus or fourteen-bus dataset.
- Choose a connected line and an analysis mode.
- Enter the requested power factor or loading values.
- Inspect the plotted branches, critical points or continuation steps.
| File | Role |
|---|---|
voltage_stability_app.m |
Graphical interface |
plot_pv_qv_curves.m |
P–V and Q–V calculations |
plot_continuation_power_flow.m |
Tangent prediction and Newton correction |
three_bus_data.m, fourteen_bus_data.m |
Example network data |
| Report | Derivations and worked studies |
Tools: MATLAB, numerical linear algebra and MATLAB graphics.
Power Flow and Network Analysis · Power System Fault Location with Machine Learning