A desktop workbench for LC-tank startup analysis: place an N-port inductor, a switched capacitor array and a cross-coupled (or transformer-coupled) gm core, and read f0, Rp, gm/gds, the startup margin and the loop gain for every code from one small-signal run. It also measures capacitor-array C/Q, C step and INL/DNL, decomposes floating-port parasitics and bundles Z11 Studio. The project was formerly named Cap Array Lab.
Tuning an LC VCO with a switched capacitor array usually means, for every code: build a testbench with port fixtures, cancel the core's transconductance device by device, run AC, and post-process by hand. Rp and the startup gain come out approximate, and the port data cannot tell which block absorbs the loss. Tank Scan Lab does this from one native run, for every code.
Frequency and Rp need the whole core, gds included. At its DC bias a cross-coupled pair is not just "−gm": it adds capacitance (Cgs, Cdb, Miller Cgd) and conductance (gds, gate loss, the RF roll-off of gm) to the tank. In the validation circuit a passive simulation of inductor + array puts f0 at 5.45 GHz, while the complete circuit starts at 4.03 GHz. The core conductance also nearly halves Rp (226 → 122 Ω), so gm·Rp and the margin taken from the passive tank would be 1.85× too optimistic. Tank Scan Lab measures the complete circuit at its operating point and reads gm and gds at the core terminals; the terminal gm already includes series-resistance degeneration (about 8 % below the device-intrinsic gm in the validation run).
Loss per module tells you what to fix. A low Rp only says that something is lossy. Every module terminal is probed and the power each block absorbs at f0 is computed (the module admittances add up to the port admittance within about 1e-13). In the validation circuit the core takes 46 % of G_loss, each inductor half 26 % and the array 1.8 %: a better array switch would barely help, while less core loading or a higher-Q inductor would. Shares change with the code (switch Ron at high-capacitance codes, off-state loading), so they are listed per code and can be plotted against the code.
Transformer-coupled cores need gm·Z21. When the gates sit on a transformer secondary, the gate swing is not the drain swing. The loop gain is gm times the drain-to-gate transimpedance Z21 of the gm-cancelled tank, not gm·Rp. Give the gate nets the pin roles P2 / N2: the tool reports gm·Z21 and the gate-to-drain ratio, and the losses on the secondary side stay in G_loss.
Capacitor arrays need more than one capacitance. Any block with a switched capacitor array (DCO/VCO banks, tunable filters, matching networks, phase shifters) needs per code: the differential C that sets the tuning, the single-ended P / N to ground parts that set common-mode behaviour and asymmetry, Q that shows switch Ron, the C step and DNL that show step uniformity, missing or non-monotonic steps, and the INL that a calibration table must correct. All of it comes from the saved SP spectrum; new observation frequencies need no rerun.
Accuracy and time. Against an independent active simulation (each core device's terminal gm cancelled with an AC-only VCCS, floating 1 A drive) the results agree within 0.03 %: Rp 122.11 vs 122.13 Ω, margin 6.470 vs 6.471, gm·Z21 of a transformer-coupled core 18.407 vs 18.407. The analysis is small-signal at the DC operating point: it gives the startup frequency and margin, not the steady-state frequency or swing (use HB or transient for those). For large arrays the linear analyses are much cheaper than HB. As an estimate for 256 codes of a complex circuit where one HB run takes 30 s: about 2 h 8 min for HB versus about 15 min for Tank Scan Lab, testbench setup excluded, scaled from the analysis-time ratio of 1 : 8.7 measured on the validation circuit.
Capacitance mode (C/Q)
- Draw circuits, connect named nets or wires, and scan decimal control registers across independent workbook pages.
- Per code: differential C and Q, split into the coupling (P-N) component, the ground-path equivalent and the single-ended P / N shunts; floating P/N total admittance.
- Show → C step / INL / DNL: capacitance step per code and endpoint-fit DNL / INL in LSB, one curve per observation frequency, with the worst |DNL| and |INL|. Derived from saved results; nothing is simulated.
Resonance / tank mode (the former Resonance and Tank scan modes, merged; old pages open in it)
- Tick what the canvas contains (inductor / N-port, cap array, gm core) to pick the passive or active backend. Per code: f0, LC-only f0, Rp(LC), Rp(LC+loading), terminal gm/gds, G_neg, startup margin, loop gain, Q, C_eff/L_eff.
- Module loss split: per-module share of G_loss at f0 from native module currents; untick it (possible without a gm core) for a fast resonance-only run (f0, Z11, Rp = Re Z).
- Optional port 2 (pin roles P2 / N2): four-port SP, Z21, and transformer-coupled cores with their gates on port 2, whose loop gain is gm·Z21. Transformer tanks with two resonances use the one with the larger margin.
- Plot manager: any number of plot tabs, each with a quantity and an x axis: per-code values, |Z11| / phase / Re / Im and |Z21| versus frequency, loop gain |T|, loss share by module. Click a curve to select its table row (and the reverse); hover for x / y. KPI tiles, plots left, results and loss tables right, all dividers draggable.
- Refine sweep at each f0: adds a 0.1 % step band around every code's f0 (overlapping windows merged) for bracket-level accuracy.
- Dark / Light theme for the whole window, canvas and plots; anti-aliased plots with a neon glow in Dark when Pillow is installed, plain Tk canvas otherwise.
- Export the results table to CSV; save self-contained workbooks with every page and its data.
See docs/TANK_SCAN.md for definitions and validation.
Also included: Touchstone (N-port) import and RF component placement in your own Cadence installation, and Z11 Studio for standalone RLC drawing, nodal analysis, linked sweeps and optimization.
Z11 Studio is a standalone RLC network workbench bundled with Tank Scan Lab, for the step before or beside a full simulation: sketch an LC network, look at its Z11, sweep and optimize component values, then turn the result into a schematic.
- Draw R, L (with Q), C and mutual coupling k with dot polarity on a multi-page canvas; save and load circuit structures from a library.
- Z11 magnitude, real, imaginary and phase versus frequency from a built-in nodal solver (no simulator needed).
- Parameter sweeps: independent sweeps multiply the number of curves; parameters in a linked group step together.
- Optimization: targets on a peak, the 3 dB bandwidth or a custom quantity (maximize, minimize, hit a value or stay in a range) with constraints; CMA-ES or differential evolution for one target, NSGA-II with a Pareto front for several; apply the best values back to the circuit.
- Export curves to CSV and figures. With a configured Cadence workspace, create the network's schematic through the Maestro plug-in.
- Open it from the Z11 Studio button in Tank Scan Lab or on its own with
caplab/z11/z11_launch. It needs NumPy and Matplotlib (see Requirements); its interface is in Chinese.
The core workbench and synthetic examples use Python 3.6+ and Tk 8.5+ with no third-party packages. A graphical display is required. Linux is the supported launch platform. Pillow is optional: with it the plots are anti-aliased (and glow in the Dark theme); without it they are drawn with plain Tk canvas items. CAPLAB_ANTIALIAS=0 forces the plain canvas (useful on RealVNC-based X servers such as Cadence's cdsXvnc, which is detected automatically), CAPLAB_ANTIALIAS=1 forces Pillow.
Z11 Studio additionally requires NumPy 1.17+ and Matplotlib 3.3+. CMA-ES optimization optionally requires cma; differential evolution and NSGA use NumPy. On Python 3.6, compatible versions include NumPy 1.19.5 and Matplotlib 3.3.4. Core Tk tests were run with Python 3.6; Z11 GUI validation used an existing modern Python environment. The Z11 numerical solver was also tested with Python 3.6 and NumPy 1.19.5.
Native library browsing, symbol import, SP measurements, module-current loss analysis and schematic creation require your own Cadence Virtuoso/Maestro/Spectre installation, library mappings, device models and licenses. None are included. EMX is not invoked by this product; provide your own Touchstone files for extracted networks.
From the repository root, open the offline example first:
python3 app.py --project examples/ideal_array.json
For the resonance / tank mode, open the synthetic tank example (analytic L, switched C and cross-coupled gm; four codes):
python3 app.py --tank --project examples/ideal_tank.json
bash tank-scan-lab.sh starts the workbench directly in the Resonance / tank mode; Load example there opens the tank example. Saved data are re-analyzed when roles or the ticked contents change; running a new scan needs your native environment.
Large-code examples (synthetic 8-bit thermometer array, codes 0–255):
python3 app.py --tank --project examples/thermo8_cq.json # C/Q, C step, INL/DNL (Capacitance mode) python3 -m caplab.thermo_example --tank # writes examples/thermo8_tank.json (~45 MB, not committed) python3 app.py --tank --project examples/thermo8_tank.json # f0, Rp, margin, gain for 256 codes
Alternatively, run bash launch.sh and click Load example. Select Ideal capacitor array for C/Q, or Parallel LC resonance (it opens in Resonance / tank: f0, Rp = Re Z and |Z11| / phase per code). Run SP / Measure C + Q replays the analytic fixture when an example page is active; its status explicitly identifies synthetic replay. Stop this page cancels it. Replay uses a fixed eight-code model and fixed saved frequency grid; editing the circuit does not change that model. Start a new workbook for native work.
The example contains no PDK or simulated device data. Its formulas, units, reproducibility and synthetic Touchstone file are described in examples/README.md.
For Z11 Studio, install optional packages in an environment you manage:
python3 -m pip install -r requirements-z11.txt bash caplab/z11/z11_launch
The Z11 Studio button opens the same bundled program. With no workspace it runs offline; with a configured native workspace it uses a source-bound schematic broker. Z11_PYTHON may select a separate interpreter. The core interface is English; Z11 retains its original Chinese interface.
Configure your own environment; no site paths or license values are bundled:
| Setting | Meaning |
|---|---|
CAPLAB_PYTHON |
GUI interpreter; defaults to python3 on PATH |
CAPLAB_WORKSPACE |
Default workspace containing your cds.lib; empty by default |
CAPLAB_LIBRARY |
Default target library name; defaults to CAP_DEMO |
CAPLAB_NATIVE_VIRTUOSO |
Native executable; defaults to virtuoso on PATH |
CAPLAB_CADENCE_ENV |
Optional trusted shell script sourced by the standalone native child |
CAPLAB_NATIVE_CDS_LIB |
Optional absolute path to a private library mapping file |
Z11_PYTHON |
Optional Z11 interpreter; otherwise uses the current GUI interpreter |
CAPLAB_Z11_PATH |
Optional external Z11 installation override; the bundled copy is the default |
Provide your Cadence and license environment yourself. GUI launch isolates Python/Tk library overrides; Maestro launch captures its native environment separately. See docs/CADENCE.md for the menu entry and configuration details. Native workflows were preserved; the tank analysis was cross-checked on native runs during development (numbers in docs/VALIDATION.md), but no native tools were run for the repository checks.
python3 app.py --help
python3 app.py --project examples/ideal_array.json
python3 app.py --tank --project examples/ideal_tank.json
python3 -m caplab.demo
python3 -m caplab.tank_example
python3 -m caplab.thermo_example [--tank] [OUT_DIR]
python3 -m unittest discover -s tests -p 'test_*.py'caplab.demo regenerates the two synthetic C/Q example files; caplab.tank_example regenerates examples/ideal_tank.json; caplab.thermo_example regenerates examples/thermo8_cq.json and, with --tank, writes the 8-bit tank workbook. --context is the internal Maestro launch-context entry, not a general netlist runner. Tests requiring Tk skip without DISPLAY; use a display assigned to you for full UI tests. The full suite includes NumPy-based Z11 tests. There is no headless native simulation CLI.
- Resonance / tank values are small-signal values at the DC operating point, i.e. a startup analysis. Steady-state oscillation frequency, swing, gain compression and phase noise need large-signal (HB / transient) simulation. Values at f0 interpolate between the two bracketing samples; use Refine sweep at each f0 for accuracy.
- Port 2 results assume the gates (or output) are on P2/N2 and port 2 is open for the one-port quantities. Loop gain gm·Z21 uses the low-frequency gm; a wrong gate polarity shows as a negative gain.
- C step / INL / DNL use an endpoint fit over the plotted code range of the selected component; they are derived from the saved C values, not from a separate simulation.
- Saved-spectrum interpolation is linear in complex admittance and never extrapolates. Coarse grids can miss narrow/high-Q resonance crossings.
- Floating P/N decomposition is a terminal equivalent, not a physical capacitor inventory. Q values do not add.
- Module loss shares require complete, balanced native current data. The synthetic C/Q example deliberately reports these as unavailable; the synthetic tank example includes module currents.
- Workbook files may contain your own local paths, library identities and results. Review them before sharing. Runtime state is written into ignored
.work/andruns/directories; Z11 has its own saved state. - The tools do not perform DRC/LVS signoff. Touchstone import accepts supported full-matrix ASCII S-parameter formats; unsupported keywords or changed files are rejected.
The following are not part of this repository:
- Your Cadence Virtuoso, Maestro and Spectre installation, library mappings, device models and licences.
- Extracted Touchstone (
.sNp) files for your inductors and transformers. EMX is not invoked by this tool. - Measured data from any real process. The example workbooks (
examples/ideal_tank.json,examples/thermo8_cq.json, ...) are synthetic.
If you need one of these, or an example for your setup, please open a GitHub issue; the maintainer will reply there.
- Lab home (all tools, narrated films and progress): https://rf-fieldwork.pages.dev/?lang=en
- This tool's page (with a narrated film): https://rf-fieldwork.pages.dev/tank/?lang=en
Other open-source tools:
- Flux Studio: parametric RF passives, EMX sweeps, multi-objective search and SNPFit
- Layout 3D Viewer: read IC layouts in 3D, locate pins and trace connections
- VCO ISF Explorer: ISF, flicker-noise up-conversion and phase-noise contributions
- Crescendo: automatic device-size optimization inside Cadence Maestro
- VCO Design Studio: five literature LC VCO topology families, packaged schematics and native export
MIT. See LICENSE.