ESP32 Arduino firmware to monitor Jbd Battery Management Systems and eSmart3 or eSmart4 chargers. Sends status to an Influx db with the Joba_JbdBms and Joba_ESmart3 libraries. Status is also sent to an mqtt broker. Switching eSmart3/4 load and JbdBms mosfets on and off via web page is also possible. For now, hardcoded battery parameters for LiFePO are always set at startup by setup_LiFePO().
Running the monitor on an ESP8266 might work but is not tested.
There are many options to compile and install an ESP32 Arduino firmware. I use this one on linux:
- Install MS Code
- Install PlatformIO as MS Code extension
- Add this folder to the MS Code workspace
- Edit platformio.ini in this folder so the usb device name for monitor and upload matches your environment
- Select build and upload the firmware
See library readmes for wiring details.
Required hardware:
- A MAX485 board (or similar) to convert RS485 signals to serial.
- A level shifter from 5V to 3.3V (at least 3 channels) if the MAX485 board does not already have one
- An ESP32 (with USB connection or an additional serial-to-USB adapter for flashing)
- Cable with one RJ45 plug and just wires on the other end. 1-8: A-, B+, nc, nc, Gnd, Gnd, 5V, 5V
- eSmart3 or eSmart4 MPPT charge controller
- JBD BMS like SP04S010A
- LiFePO battery, PV (or >16V power supply for testing)
RJ45 plug
for eSmart3
__
__/__\__
|front |
||||||||
1 ... 8
ABxx--++
Relevant connection data (Influx host, database, ...) is configured in platformio.ini
Create necessary database like this on the influx server: influx --execute 'create database LiFePO_Island'
- checks eSmart3 Information every 10 minutes
- checks eSmart3 ChgSts every half second
- checks eSmart3 BatParam, LoadParam, ProParam every minute
- checks eSmart Log(wStartCnt, wFaultCnt, dwTotalEng, dwLoadTotalEng, wBacklightTime, bSwitchEnable) every minute
- checks JbdBms Hardware every 10 minutes
- checks JbdBms Cells every 10 seconds
- checks JbdBms Status every 10 seconds
- updates database at startup and on changes
job4:~ > influx -precision rfc3339 --database LiFePO_Island --execute 'show measurements'
name: measurements
name
----
BatParam
Cells
ChgSts
Hardware
Information
LoadParam
Log
Parameters
ProParam
Status
job4:~ > influx -precision rfc3339 --database LiFePO_Island --execute 'select * from Cells limit 5'
name: Cells
time Host Id Version voltage1 voltage2 voltage3 voltage4
---- ---- -- ------- -------- -------- -------- --------
2022-11-01T09:49:39Z lifepo_island-1 JBD-SP04S010A-L4S-35A-B 1.0 3360 3356 3356 3355
2022-11-01T09:49:45Z lifepo_island-1 JBD-SP04S010A-L4S-35A-B 1.0 3360 3357 3356 3356
2022-11-01T09:49:52Z lifepo_island-1 JBD-SP04S010A-L4S-35A-B 1.0 3360 3356 3356 3356
2022-11-01T09:49:58Z lifepo_island-1 JBD-SP04S010A-L4S-35A-B 1.0 3361 3357 3356 3356
2022-11-01T09:50:05Z lifepo_island-1 JBD-SP04S010A-L4S-35A-B 1.0 3361 3356 3356 3356
since WiFi is needed for Influx anyways, it is used for other stuff as well:
- Webserver
- display links for JSON of all eSmart3 item categories and JbdBms commands
- enables OTA firmware update
- later: display and change some values of BatParam, LoadParam, ProParam and Log
- Syslog and mqtt publish of status on changes
- mqtt topic LiFePO_Island/{instance}/json/# for publishing eSmart3/4 or JBD infos in json format
- mqtt topic LiFePO_Island/{instance}/status/# for publishing esmart3/4 or jbd fault status
- mqtt topic LiFePO_Island/{instance}/cmd for receiving commands:
- "load on": switch eSmart3/4 load on
- "load off": switch eSmart3/4 load off
- NTP to set eSmart3/4 time at startup once
- RSSI and BSSID monitoring to find a place with good WLAN signal reception for the ESP32
- The start page shows the key values live (SoC, V/A/W, PV, load, cells,
temperatures, faults, link state) and their age; data comes from
GET /api/live. Load and MOSFETs are switched withPOST /api/loadandPOST /api/mosfets; the old form endpoints still work. - InfluxDB writes are batched (one POST every 5 s, retried with backoff, ms timestamps) instead of one POST per change.
pio test -e nativeruns the unit tests; envsmhetesp32minikit_benchandxiao_esp32c6_benchbuild a silent simulator firmware for the test bench (own instance, database and Wi-Fi), andtest/system/check_device.pytests a running device.- The protection limits stored in the BMS (cell/pack under and over voltage,
current and temperature limits, balancer) can be read on request from the
page (Read from BMS, admin login) or
POST /api/bmsparam; they are published asBmsParam(see docs/spec-webui.md). - JSON now carries
"Version"as a string. - Home Assistant MQTT discovery: device
LiFePO_Island <instance>with 26 entities; migration of the former hand-written YAML entities withtools/ha_migrate.py(docs/admin.md).
Documentation: docs/spec.md (architecture and decisions), docs/spec-webui.md, docs/spec-telemetry.md, docs/spec-homeassistant.md, docs/user.md, docs/admin.md, docs/test.md.
Comments welcome
Joachim Banzhaf
The [syslog], [mqtt], [influx] and [ntp] servers in platformio.ini are only defaults,
now the service aliases syslog, mqtt and influx. A change needs no rebuild: it is validated,
stored in NVS (ESP32; separate from the EEPROM sector with the static IP config) and active after
the reboot that follows 1 s later (reboot=0 suppresses it). ESP8266 builds keep the defaults.
curl -u admin:<pw> -X POST http://lifepo_island-1/api/netconfig -d mqttHost=mqtt -d influxHost=influx
curl -u admin:<pw> -X POST http://lifepo_island-1/api/netconfig -d defaults=1
curl http://lifepo_island-1/api/netconfig # active values, source, defaults
curl http://lifepo_island-1/api/netstatus # firmware, WiFi, syslog/MQTT/InfluxDB/NTP with last result
Fields: syslogHost, syslogPort, mqttHost, mqttPort, influxHost, influxPort, ntp.
Host names only (letters, digits, -, .; empty = off), ports 1..65535; a bad value gives
400 {"error":"invalid value","field":...} and nothing is stored.
/update, /reset, /ip and POST /api/netconfig need the user admin and the password
from secrets.ini (untracked, mode 600; see secrets.ini.template). pio_secrets.py compiles it
in, and upload_script.py uses it for OTA. Load and mosfet switching stay open. Without
secrets.ini there is no lock ("adminLock": false).
Note: the ESP8266 env d1_mini_ota does not build (it already did not before 4.1): ip_config()
uses the ESP32-only EEPROM API (writeBytes, readULong, bool begin).