Note
This repository is archived and no longer actively maintained.
Script to retrieve current Solar PV data from the Solarman API, and send Power (W) and Energy (kWh) metrics to a MQTT broker, for further use in home automation. Several PV vendors use the Solarman Smart platform for statistics. One example is the Trannergy PV converter.
usage: run.py [-h] [-d] [-s] [-i INTERVAL] [-f FILE] [--validate] [--create-passhash CREATE_PASSHASH] [-v] Collect data from Trannergy / Solarman API optional arguments: -h, --help show this help message and exit -d, --daemon run as a service -s, --single single run and exit -i INTERVAL, --interval INTERVAL run interval in seconds (default 300 sec.) -f FILE, --file FILE config file (default ./config.json) --validate validate config file and exit --create-passhash CREATE_PASSHASH create passhash from provided passwordand exit
You can run this script as a Docker container or in Python 3. Either way, a configuration file is required. Use the sample config.sample.json file in this repository for reference. Also, a Solarman API appid+secret is required, which can be requested via [email protected].
Create a new config file by copying the sample config file and filling in the required information.
The first part covers your SolarmanPV account:
{
"name": "Trannergy",
"url": "globalapi.solarmanpv.com",
"appid": "",
"secret": "",
"username": "",
"passhash": "",
[..]
}- name: is free text to identify the platform.
- url: is the base URL of the API.
- appid: is the appid for the API (See Usage).
- secret: is the secret for the API (See Usage).
- username: is the username for the API (emailadres).
- passhash: is a sha256 hash of your password. This can be generated via
--create-passhash.
The second part covers the PV inverter and logger ID's. These can be retrieved via the Solarman API.
{
[..]
"stationId": 123,
"inverterId": 456,
"loggerId": 789
[..]
}- stationId: is the ID of the station. This is the value of
stationList[0].id.
curl --location --request POST 'https://globalapi.solarmanpv.com/station/v1.0/list?language=en' \ --header 'Content-Type: application/json' \ --header 'Authorization: bearer TOKEN' \ --data-raw '{"size":20,"page":1}'
- inverterId: is the SN of the inverter. This is the value of
deviceListItems[0].deviceSn. - For Bosswerk MI300 and MI600 use "MICRO_INVERTER" instead of "INVERTER".
curl --location --request POST 'https://globalapi.solarmanpv.com/station/v1.0/device?language=en' \ --header 'Content-Type: application/json' \ --header 'Authorization: bearer TOKEN' \ --data-raw '{"size":10,"page":1,"stationId":1234567,"deviceType":"INVERTER"}'
- loggerId: is the SN of the logger. This is the value of
deviceListItems[0].deviceSn.
curl --location --request POST 'https://globalapi.solarmanpv.com/station/v1.0/device?language=en' \ --header 'Content-Type: application/json' \ --header 'Authorization: bearer TOKEN' \ --data-raw '{"size":10,"page":1,"stationId":1234567,"deviceType":"COLLECTOR"}'
- meterId (optional): If you have a DTSD422 meter as part of your PV system, you can add the meter serialnumber to the config file.
{
[..]
"meterId": 123
[..]
}A bearer TOKEN to use in the requests above can be retrieved by adding your APPID, APPSECRET, USERNAME, PASSHASH in this request:
curl --location --request POST 'https://globalapi.solarmanpv.com/account/v1.0/token?appId=APPID&language=en' \ --header 'Content-Type: application/json' \ --data-raw '{ "appSecret": "APPSECRET", "email": "USERNAME", "password": "PASSHASH" }'
Note: If there is an error with AUTH_INVALID_USERNAME_OR_PASSWORD as code it might be that your password is too long or contains special characters. Try something shorter and A-Z, a-z and 0-9 only.
The final section covers the MQTT broker, to where the metrics will be published.
{
[..]
"broker": "mqtt.example.com",
"port": 1883,
"topic": "solarman",
"username": "",
"password": ""
}The following topics are published to the MQTT broker. Topics and fields may differ between PV system types. The example output below use solarmanpv as the topic, configured in the config file.
Information about the plant, current power and last update time.
solarmanpv/station/batteryPower
solarmanpv/station/batterySoc
solarmanpv/station/chargePower
solarmanpv/station/dischargePower
solarmanpv/station/generationPower
solarmanpv/station/gridPower
solarmanpv/station/irradiateIntensity
solarmanpv/station/lastUpdateTime
solarmanpv/station/purchasePower
solarmanpv/station/usePower
solarmanpv/station/wirePower
Inverter information.
solarmanpv/inverter/deviceId
solarmanpv/inverter/deviceSn
solarmanpv/inverter/deviceState
solarmanpv/inverter/deviceType
solarmanpv/inverter/attributes
The attributes field contains all inverter datalist entries as a JSON object. An expample set of attributes is shown below:
SN: XXXXXXXXXX
Device_Type: 4
Production_Compliance_Type: 0
Rated_Power: 300.00
Year: 48
Month: 0
Day: 0
Hour: 0
Minute: 0
Seconds: 0
Communication_Protocol_Version: V0.2.0.1
Control_Board_Firmware_Version: V0.1.1.2
Communication_Board_Firmware_Version: V0.2.0.7
DC_Voltage_PV1: 0.00
DC_Voltage_PV2: 0.00
DC_Voltage_PV3: 0.00
DC_Voltage_PV4: 0.00
DC_Current_PV1: 0.00
DC_Current_PV2: 0.00
DC_Current_PV3: 0.00
DC_Current_PV4: 0.00
DC_Power_PV1: 0.00
DC_Power_PV2: 0.00
DC_Power_PV3: 0.00
DC_Power_PV4: 0.00
AC_Voltage_1: 0.00
AC_Current_1: 0.00
Total_AC_Output_Power(Active): 0
AC_Output_Frequency_1: 0.00
Total_Production(Active): 2.50
Total_Production_1: 2.50
Total_Production_2: 0.00
Total_Production_3: 0.00
Total_Production_4: 0.00
Daily_Production(Active): 0.70
Daily_Production_1: 0.70
Daily_Production_2: 0.00
Daily_Production_3: 0.00
Daily_Production_4: 0.00
AC_Radiator_Temp: -10.00
Micro_Inverter_Port_1: XXXXXXXXXX-1
Micro_Inverter_Port_2: XXXXXXXXXX-2
Micro_Inverter_Port_3: XXXXXXXXXX-3
Micro_Inverter_Port_4: XXXXXXXXXX-4
Number_Of_MPPT_Paths: 1
Number_Of_Phases: 1
Running_Status: 4
Overfrequency_And_Load_Reduction_Starting_Point: 50.20
Islanding Protection Enabled: Enable
Overfrequency_And_Load_Reduction_Percentage: 44
GFDI Enabled: Disable
Grid-connected Standard: 0
Grid Voltage_Upper_Limit: 275.00
Grid Voltage_Lower_Limit: 180.00
Grid Frequency_Upper_Limit: 52.00
Grid Frequency_Lower_Limit: 47.50
Start-up Self-checking Time: 60
solarmanpv/logger/deviceId
solarmanpv/logger/deviceSn
solarmanpv/logger/deviceState
solarmanpv/logger/deviceType
solarmanpv/logger/attributes
The attributes field contains all inverter datalist entries as a JSON object. Some devices may send an empty object for this field.
An example set of attributes is shown below:
Embedded_Device_SN: XXXXXXXXXX Module_Version_No: MW3_15_5406_1.35 Extended_System_Version: V1.1.00.07 Total_running_time: 1 Offset_time: 1634486607 Data_Uploading_Period: 5 Data_Acquisition_Period: 60 Max._No._of_Connected_Devices: 1 Signal_Strength: 100 Heart_Rate: 120 IV_Curve_Supported: 1 Batch_Command_Supported: 1 Support_Reporting_Upgrading_Progress: 0 AT+UPGRADE_Command_Supported: 255 Method_Of_Protocol_Upgrade: 255
If you have multiple inverter stations, you can add them to the config file as a list. Make sure to publish to separate MQTT topics per inverter instance, and configure the Home Assistant MQTT sensors accordingly.
[
{
"name": "Trannergy-1",
"stationId": 987,
"inverterId": 654,
"loggerId": 321,
"mqtt": {
"topic": "inverter1"
}
},
{
"name": "Trannergy-2",
"stationId": 123,
"inverterId": 456,
"loggerId": 789,
"mqtt": {
"topic": "inverter2"
}
}
]Minimized example config; see config.sample.json for all fields.
mqtt: sensor: - name: "solarmanpv_station_generationPower" state_topic: "solarmanpv/station/generationPower" unique_id: "generatedPower" unit_of_measurement: "Wh" device_class: energy state_class: measurement
Repeat for every station topic needed.
- name: "solarmanpv_inverter" unique_id: "solarmanpv_inverter" state_topic: "solarmanpv/inverter/deviceState" json_attributes_topic: "solarmanpv/inverter/attributes" - name: "solarmanpv_logger" unique_id: "solarmanpv_logger" state_topic: "solarmanpv/logger/deviceState" json_attributes_topic: "solarmanpv/logger/attributes" sensor: - platform: template sensors: solarmanpv_inverter_device_state: unique_id: "inverter_device_state" value_template: >- {% set mapper = { '1' : 'Online', '2' : 'Failure', '3' : 'Offline'} %} {% set state = states.sensor.solarmanpv_inverter.state %} {{ mapper[state] if state in mapper else 'Unknown' }} - platform: template sensors: solarmanpv_logger_device_state: unique_id: "logger_device_state" value_template: >- {% set mapper = { '1' : 'Online', '2' : 'Failure', '3' : 'Offline'} %} {% set state = states.sensor.solarmanpv_logger.state %} {{ mapper[state] if state in mapper else 'Unknown' }}
template: - sensor: - name: "Solarman energy daily" unique_id: "solarman_energy_daily" unit_of_measurement: 'kWh' state: "{{ state_attr('sensor.solarmanpv_inverter', 'Daily_Production_(Active)') }}" device_class: energy state_class: measurement attributes: last_reset: '1970-01-01T00:00:00+00:00' - sensor: - name: solarmanpv_inverter_dc_voltage_pv1 unique_id: "solarmanpv_inverter_dc_voltage_pv1" unit_of_measurement: 'V' state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Voltage_PV1') }}" state_class: measurement - sensor: - name: solarmanpv_inverter_dc_current_pv1 unique_id: "solarmanpv_inverter_dc_current_pv1" unit_of_measurement: 'A' state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Current_PV1') }}" state_class: measurement - sensor: - name: solarmanpv_inverter_dc_voltage_testing unique_id: "solarmanpv_inverter_dc_current_testing" unit_of_measurement: 'V' state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Voltage_PV1') }}" state_class: measurement unit_of_measurement: 'A' state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Current_PV1') }}" state_class: measurement - sensor: - name: solarmanpv_inverter_dc_voltage_pv2 unique_id: " solarmanpv_inverter_dc_voltage_pv2" unit_of_measurement: 'V' state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Voltage_PV2') }}" state_class: measurement - sensor: - name: solarmanpv_inverter_dc_current_pv2 unique_id: "solarmanpv_inverter_dc_current_pv2" unit_of_measurement: 'A' state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Current_PV2') }}" state_class: measurement - sensor: - name: solarmanpv_inverter_dc_power_pv1 unique_id: "solarmanpv_inverter_dc_power_pv1" unit_of_measurement: 'W' state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Power_PV1') }}" state_class: measurement - sensor: - name: solarmanpv_inverter_dc_power_pv2 unique_id: "solarmanpv_inverter_dc_power_pv2" unit_of_measurement: 'W' state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Power_PV2') }}" state_class: measurement - sensor: - name: solarmanpv_inverter_total_production unique_id: "solarmanpv_inverter_total_production" unit_of_measurement: 'kWh' state: "{{ state_attr('sensor.solarmanpv_inverter', 'Cumulative_Production_(Active)') }}" state_class: total_increasing - sensor: - name: solarmanpv_inverter_daily_production unique_id: "solarmanpv_inverter_daily_production" unit_of_measurement: 'kWh' state: "{{ state_attr('sensor.solarmanpv_inverter', 'Daily_Production_(Active)') }}" state_class: total_increasing - sensor: - name: solarmanpv_inverter_ac_radiator_temp unique_id: "solarmanpv_inverter_ac_radiator_temp" unit_of_measurement: '°C' state: "{{ state_attr('sensor.solarmanpv_inverter', 'Temperature-_Inverter') }}" state_class: measurement - sensor: - name: solarmanpv_inverter_ac_voltage_1 unique_id: "solarmanpv_inverter_ac_voltage_1" unit_of_measurement: 'V' state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Voltage_R/U/A') }}" state_class: measurement - sensor: - name: solarmanpv_inverter_ac_current_1 unique_id: "solarmanpv_inverter_ac_current_1" unit_of_measurement: 'A' state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Current_R/U/A') }}" state_class: measurement - sensor: - name: solarmanpv_inverter_ac_voltage_2 unique_id: "solarmanpv_inverter_ac_volgage_2" unit_of_measurement: 'V' state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Voltage_S/V/B') }}" state_class: measurement - sensor: - name: solarmanpv_inverter_ac_current_2 unique_id: "solarmanpv_inverter_ac_current_2" unit_of_measurement: 'A' state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Current_S/V/B') }}" state_class: measurement - sensor: - name: solarmanpv_inverter_ac_voltage_3 unique_id: "solarmanpv_inverter_ac_voltage_3" unit_of_measurement: 'V' state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Voltage_T/W/C') }}" state_class: measurement - sensor: - name: solarmanpv_inverter_ac_current_3 unique_id: "solarmanpv_inverter_ac_current_3" unit_of_measurement: 'A' state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Current_T/W/C') }}" state_class: measurement - sensor: - name: solarmanpv_inverter_ac_output_frequency unique_id: "solarmanpv_inverter_ac_output_frequency" unit_of_measurement: 'Hz' state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Output_Frequency_R') }}" state_class: measurement
The easiest way to run is via a container. Current version is available at https://github.com/mpepping/solarman-mqtt/pkgs/container/solarman-mqtt
Docker example to run this script every 5 minutes and providing a config file:
cd /opt git clone https://github.com/mpepping/solarman-mqtt cd solarman-mqtt mv config.sample.json config.json # setup your config sudo docker run --name solarman-mqtt -d --restart unless-stopped -v /opt/solarman-mqtt:/opt/app-root/src ghcr.io/mpepping/solarman-mqtt:latest
This docker-compose.yml example can be used with docker-compose or podman-compose
version: '3' services: solarman-mqtt: image: ghcr.io/mpepping/solarman-mqtt:latest container_name: "solarman-mqtt" environment: - TZ=Europe/Berlin volumes: - /opt/solarman-mqtt/config.json:/opt/app-root/src/config.json # or mount your complete config directory restart: unless-stopped
Run pip install -r requirements.txt and start python3 run.py.