GeezerVisonThe World Wide Web, restored to 800 pixels of glory. | ||||||||||||||
| Home|About|Gaming cabinet|Archives|How it works|Starter sites | ||||||||||||||
GeezerVison is showing github.com — Fix IndexOutOfBoundsException from mismatched varint length in Http3FrameCodec by normanmaurer · Pull Request #17523 · netty/netty Conversation
Member
Motivation: decodeFrame() and decodeSettings() checked that the buffer held at Modifications: Validate the integer's encoded length against the declared payload Result: Correctly handle varint lenght parsing
Sorry, something went wrong. Uh oh!
There was an error while loading. Please reload this page. All reactions…rameCodec Motivation: decodeFrame() and decodeSettings() checked that the buffer held at least the frame's declared payload length, but the length of the variable-length integer(s) inside that payload is derived from the integer's own first byte, independent of the declared payload length. A CANCEL_PUSH/GO_AWAY/MAX_PUSH_ID/PUSH_PROMISE frame (or a SETTINGS key/value) whose declared length was shorter than what its own prefix bits require caused readVariableLengthInteger() to call readLong()/readInt()/etc. past what was verified available, throwing a raw IndexOutOfBoundsException instead of failing the connection with H3_FRAME_ERROR. Modifications: Validate the integer's encoded length against the declared payload length before reading it, and add regression tests for each affected frame type plus both SETTINGS key and value lengths. Result: Correctly handle varint lenght parsing
yawkat
approved these changes
|
There was an error while loading. Please reload this page.
✅ All tests passed ✅Test SummaryBuild PR / linux-x86_64-java24 build > Netty/Handler/Ssl/Ocsp
Build PR / macos-x86_64-java11-boringssl build > Netty/Transport/Native/KQueue
🏷️ Commit: c1107f7 Test FailuresOcspServerCertificateValidatorTest (Netty/Handler/Ssl/Ocsp in Build PR / linux-x86_64-java24 build | Attempt 1/2)KQueueDatagramUnicastIPv6MappedTest > testSimpleSendDirectByteBuf(TestInfo) (Netty/Transport/Native/KQueue in Build PR / macos-x86_64-java11-boringssl build | Attempt 1/2)Learn more about TestLens at testlens.app/docs. |
Sorry, something went wrong.
There was an error while loading. Please reload this page.
There was an error while loading. Please reload this page.
|
Auto-port PR for 5.0: #17560 |
Sorry, something went wrong.
There was an error while loading. Please reload this page.
…ength in Http3FrameCodec (#17560) Auto-port of #17523 to 5.0 Cherry-picked commit: ae1798a --- Motivation: decodeFrame() and decodeSettings() checked that the buffer held at least the frame's declared payload length, but the length of the variable-length integer(s) inside that payload is derived from the integer's own first byte, independent of the declared payload length. A CANCEL_PUSH/GO_AWAY/MAX_PUSH_ID/PUSH_PROMISE frame (or a SETTINGS key/value) whose declared length was shorter than what its own prefix bits require caused readVariableLengthInteger() to call readLong()/readInt()/etc. past what was verified available, throwing a raw IndexOutOfBoundsException instead of failing the connection with H3_FRAME_ERROR. Modifications: Validate the integer's encoded length against the declared payload length before reading it, and add regression tests for each affected frame type plus both SETTINGS key and value lengths. Result: Correctly handle varint lenght parsing Co-authored-by: Norman Maurer <[email protected]>
Motivation: This is an additional fix for PR #17523. The check added with PR #17523 reads the first byte of the variable length integer, a frame with a declared zero length doesn't have such byte. Modification: - Add a payload length check - Add junit tests Result: Frames with zero length payloads fail with H3_FRAME_ERROR
#17572) Auto-port of #17564 to 5.0 Cherry-picked commit: 8cca995 --- Motivation: This is an additional fix for PR #17523. The check added with PR #17523 reads the first byte of the variable length integer, a frame with a declared zero length doesn't have such byte. Modification: - Add a payload length check - Add junit tests Result: Frames with zero length payloads fail with H3_FRAME_ERROR Co-authored-by: Violeta Georgieva <[email protected]>
#17571) Motivation: Http3FrameCodec.enforceExactIdLength() (added in #17523) rejects CANCEL_PUSH, GO_AWAY and MAX_PUSH_ID frames whose declared payload length does not exactly match the encoded width of their single push-id/stream-id varint. That fix already covers a declared length shorter than the varint's width, but there was no test asserting the opposite direction: a declared length longer than the varint's width, which would otherwise leave unread trailing bytes in the buffer to be mis-parsed as the type/length/payload of a bogus subsequent frame, desynchronizing the control stream. Modifications: Add parameterized tests for all three frame types that send a payload declared as the maximum 8 bytes but containing only a 1-byte varint followed by 7 trailing bytes shaped like a HEADERS frame header. Assert the connection is closed with H3_FRAME_ERROR and that no frame, legitimate or smuggled, is produced from the trailing bytes. Result: Explicit regression coverage for the control-stream desynchronization scenario. This is a followup to #17523
…D trailing bytes (#17585) Auto-port of #17571 to 5.0 Cherry-picked commit: 68466e3 --- Motivation: Http3FrameCodec.enforceExactIdLength() (added in #17523) rejects CANCEL_PUSH, GO_AWAY and MAX_PUSH_ID frames whose declared payload length does not exactly match the encoded width of their single push-id/stream-id varint. That fix already covers a declared length shorter than the varint's width, but there was no test asserting the opposite direction: a declared length longer than the varint's width, which would otherwise leave unread trailing bytes in the buffer to be mis-parsed as the type/length/payload of a bogus subsequent frame, desynchronizing the control stream. Modifications: Add parameterized tests for all three frame types that send a payload declared as the maximum 8 bytes but containing only a 1-byte varint followed by 7 trailing bytes shaped like a HEADERS frame header. Assert the connection is closed with H3_FRAME_ERROR and that no frame, legitimate or smuggled, is produced from the trailing bytes. Result: Explicit regression coverage for the control-stream desynchronization scenario. This is a followup to #17523 Co-authored-by: Norman Maurer <[email protected]>
There was an error while loading. Please reload this page.
Successfully merging this pull request may close these issues.
There was an error while loading. Please reload this page.