GV

GeezerVison

The World Wide Web, restored to 800 pixels of glory.

Home|About|Gaming cabinet|Archives|How it works|Starter sites

On this site

  • Sign in
  • ActionsCI/CD and automation
  • CodespacesCloud development environments
  • All Features
  • Documentation
  • Training
  • Certifications
  • Build with Copilot
  • Customize Copilot
  • Integrations
  • Trending repos
  • GitHub Sponsors
  • Developer articles
  • Enterprises

This view

  • Original page
  • New address

GeezerVison is showing github.com — GitHub - onsmam/HA-Alphaess-vitapower: AlphaESS VitaPower 3600 AC battery for Home Assistant over Modbus TCP

BranchesTags
Open more actions menu

Latest commit

 

History

10 Commits
10 Commits

Folders and files

NameName
Last commit message
Last commit date
.github
.github
 
 
config
config
 
 
core
core
 
 
custom_components
custom_components
 
 
docs
docs
 
 
examples
examples
 
 
library
library
 
 
scripts
scripts
 
 
tests
tests
 
 
tools
tools
 
 
.devcontainer.json
.devcontainer.json
 
 
.gitattributes
.gitattributes
 
 
.gitignore
.gitignore
 
 
.ruff.toml
.ruff.toml
 
 
CONTRIBUTING.md
CONTRIBUTING.md
 
 
LICENSE
LICENSE
 
 
README.md
README.md
 
 
hacs.json
hacs.json
 
 
pytest.ini
pytest.ini
 
 
requirements_common.txt
requirements_common.txt
 
 
requirements_dev.txt
requirements_dev.txt
 
 
requirements_lint.txt
requirements_lint.txt
 
 
requirements_test.txt
requirements_test.txt
 
 

Repository files navigation

AlphaESS VitaPower for Home Assistant

Read an AlphaESS VitaPower 3600 AC battery over Modbus TCP, on Home Assistant 2026.10 or newer, using the shared Modbus connections Home Assistant's Modbus integration hands out (homeassistant.components.modbus.async_get_unit).

Warning

The readings have been checked against a real VitaPower and its app; the remote control has been tested on one VitaPower with scripts (tools/vitapower_dispatch_test.py), not yet through Home Assistant. Writing to the battery is at your own risk.

This repository holds three things:

Folder What Modelled on
library/ alphaess-modbus-vitapower, the standalone device library on modbus-connection darkrain-nl/sofar-modbus
core/ the integration as it would be contributed to Home Assistant Core homeassistant/components/sofar
custom_components/ the same integration for HACS, with the library vendored ludeeus/integration_blueprint

custom_components/ and tests/ are generated from core/ and library/ by scripts/sync_custom.py; CI fails when they drift.

Installation (HACS)

  1. Remove any other Modbus connection to the battery first — such as a YAML modbus: hub — and restart. The VitaPower accepts a single Modbus TCP client, and a YAML hub opens a link of its own rather than sharing one.
  2. HACS → ⋮ → Custom repositories → https://github.com/onsmam/HA-Alphaess-vitapower, type Integration.
  3. Download AlphaESS VitaPower (Modbus) and restart Home Assistant.
  4. Settings → Devices & services → Add integration → AlphaESS VitaPower: the IP address of the battery's LAN port (Wi-Fi serves no Modbus), port 502, unit ID 85.

The battery's serial number becomes the entry's unique ID; after an IP change use Reconfigure on the integration.

Entities

Power and current are + discharging, − charging, as the energy dashboard expects. Readings refresh every 5 s, the configured limits every 5 minutes.

Entities
Battery state of charge, voltage, current, battery (DC) power, state of health, lowest/highest cell voltage and temperature, BMS charge/discharge power limits, capacity
Energy energy charged, discharged, charged from grid (total_increasing; the battery updates them in batches, minutes behind)
Inverter AC power, grid voltage, AC current, grid frequency, inverter temperature, conversion efficiency (worked out; unknown below 300 W)
Dispatch remote dispatch running (the vendor's cloud controls the battery through it), dispatch power, state-of-charge target, duration
Settings discharge and charge cut-off state of charge, maximum feed-in
Faults battery warning, battery fault, inverter fault, system fault (on for any bit; the codes are in the diagnostics)

For the energy dashboard: battery in sensor.vitapower_energy_charged, out sensor.vitapower_energy_discharged, power sensor.vitapower_ac_power.

Control (Day Ahead Optimizer)

Two entities control the battery through its dispatch block:

Entity What it does
select.vitapower_control_mode on: follow the setpoint. off: hold the battery idle at 0 W. auto (default): write nothing, the battery follows the mode set in the app
number.vitapower_power_setpoint W, + charges, − discharges (as DAO writes it), −3680 to 3680

While the mode is on or off the command is written again every 60 s and lasts 300 s in the battery: if Home Assistant stops, the battery takes control back itself within 5 minutes. Charging aims for the charge cut-off and discharging for the discharge cut-off, which the battery also enforces itself. Both entities come back as they were after a restart. If another client — such as the AlphaESS cloud — writes its own command, a warning is logged and the command is written again at the next renewal.

Wiring DAO

As in DAO's AlphaESS examples, let DAO write three helpers and copy them over with an automation. Create:

Helper Type Settings
input_number.dao_vitapower_vermogen Number −3680 to 3680, step 1, W
input_select.dao_vitapower_modus Dropdown Aan, Uit
input_boolean.dao_vitapower_balanceren Toggle

In DAO's battery settings:

"entity set power feedin": "input_number.dao_vitapower_vermogen",
"entity set operating mode": "input_select.dao_vitapower_modus",

and in its grid settings:

"entity balance switch": "input_boolean.dao_vitapower_balanceren",

Leave entity stop inverter unset. The automation needs no timers, durations or SOC targets: the integration renews the command and picks the targets.

examples/dao_vitapower_automation.yaml is the automation, ready to paste in Settings → Automations → Create automation → ⋮ → Edit in YAML. It checks, in this order:

DAO Control mode Battery
balance switch on auto its own mode: with the app on self-consumption, it follows the grid meter to keep it at 0
Aan, setpoint + or − on charges (+) or discharges (−) at the setpoint, up to 3680 W, also to feed in when prices are high
Uit off idle at 0 W, as DAO planned it

DAO chooses per interval: a fixed setpoint follows its plan exactly, including discharging at full power to sell, but the difference between its forecast and the real house load goes to or comes from the grid; balancing makes up that difference, but feeds in no more than the house uses. The automation also runs when Home Assistant starts, so the battery is back on DAO's plan after a restart.

For Uit to hand the battery back to the app instead (as in the wiki), use auto in place of off in the automation's default.

With an EV charger

Balancing follows the grid meter, which also sees the car: while the car charges the battery would discharge into it. examples/dao_vitapower_automation_ev.yaml replaces the automation above for a house with a charger. While the car charges it recomputes every 15 s:

DAO Battery while the car charges
balance switch on balances the house as if the car were not there: discharges what the house needs, or charges with the sun left over
Aan, − setpoint discharges as DAO planned
Aan, + setpoint charges as DAO planned, as far as the battery's phase stays within the main fuse (25 A)
Uit idle at 0 W

It needs the charger's status and power, the grid power, and the power, current and voltage on the battery's phase; the file lists which entities to replace. Because the battery's own power drops out of the sums, a copy that writes to two helpers instead of the battery's entities shows what it would do without touching the battery.

DAO may also be pointed at the two entities directly ("entity set power feedin": "number.vitapower_power_setpoint", "entity set operating mode": "select.vitapower_control_mode", with "entity set operating mode on": "on" and "entity set operating mode off": "off"). That has not been tried; if DAO's log reports Fout bij schrijven naar …, use the helpers.

Efficiency measured on the battery, for DAO's charge and discharge stages: charging 89.7 % at 300 W and about 95 % at 3600 W (DC over AC); discharging 93 % at 800 W. Below a few hundred watts the readings are too coarse to tell.

Development

The custom integration follows the blueprint:

scripts/setup
scripts/develop
scripts/lint

Change the integration in core/ and the device in library/, then regenerate custom_components/ and tests/ (needs ruff and a Home Assistant install for the strings [%key:…] references resolve against):

python3 scripts/sync_custom.py

Run the custom integration's tests, and the library's:

pip install -r requirements_test.txt && pytest
cd library && uv sync && uv run pytest

docs/VITAPOWER_MODBUS.md has the register map and how it was verified; docs/scans the scans, with the serial number replaced (tools/redact_scan.py). tools/modbus_scan.py is the read-only scanner they were taken with, tools/vitapower_live.py prints every value to compare with the app, tools/vitapower_dispatch_test.py runs one confirmed dispatch test, and examples/vitapower_yaml_package.yaml the YAML package this replaces.

The icon and logo Home Assistant shows are in custom_components/alphaess_modbus_vitapower/brand/; scripts/sync_custom.py keeps them as they are.

Releases

The HACS integration is released with bare version tags (0.2.0), the version kept in custom_components/VERSION; the library with library- tags, see library/RELEASING.md.

Nederlands — snel installeren

  1. Verwijder eerst je YAML modbus:-package voor de VitaPower en herstart (de batterij accepteert maar één client).

  2. HACS → ⋮ → Aangepaste repositories → deze repo, type Integratie → downloaden → herstarten.

  3. Instellingen → Apparaten & diensten → Integratie toevoegen → AlphaESS VitaPower: IP van de LAN-poort, poort 502, unit-ID 85.

  4. Bediening via DAO: maak de drie helpers uit Wiring DAO hierboven, zet ze in DAO en plak examples/dao_vitapower_automation.yaml als automation (Instellingen → Automatiseringen → Nieuw → ⋮ → Bewerken in YAML).

    • DAO balanceren aan → auto: de batterij volgt zijn eigen modus (app op Eigen verbruik: nul op de meter).
    • DAO Aan → on: laden (+) of ontladen (−) op het vermogen van DAO, ook maximaal terugleveren.
    • DAO Uit → off: stil op 0 W.

    Control mode staat standaard op auto: er wordt niets geschreven tot DAO hem op Aan of Uit zet.

  5. Laadpaal: gebruik examples/dao_vitapower_automation_ev.yaml. Terwijl de auto laadt balanceert de accu alsof de auto er niet is (geen accustroom naar de auto) en laadt hij alleen zolang zijn fase onder de 25 A blijft. Vervang de sensoren bovenin het bestand door die van jou.

About

AlphaESS VitaPower 3600 AC battery for Home Assistant over Modbus TCP

Topics

alphaessalphaess-modbushacs-integrationhome-assistanthome-assistant-hacsmodbus-tcp

Resources

Readme
Apache-2.0 license

Contributing

Contributing
Activity

Stars

0 stars

Watchers

0 watching

Forks

0 forks
Report repository

Releases

Packages

Contributors

Languages