GeezerVison is showing github.com — GitHub - parallaxmetrology/he-checks: Quiet failures in H&E pipelines and colorectal datasets: Macenko stain vectors collapsed by an SVD sign convention, 25 TCGA slides (and their archive tiles) with ~2x wrong pixel spacing, and purple 'blank glass' in CRC-VAL-HE-7K.

BranchesTags
Open more actions menu

Latest commit

 

History

3 Commits
3 Commits

Folders and files

NameName
Last commit message
Last commit date
.github
.github
 
 
data
data
 
 
docs
docs
 
 
examples
examples
 
 
src/hechecks
src/hechecks
 
 
tests
tests
 
 
.gitignore
.gitignore
 
 
CHANGELOG.md
CHANGELOG.md
 
 
CITATION.cff
CITATION.cff
 
 
LICENSE
LICENSE
 
 
LICENSE-CONTENT
LICENSE-CONTENT
 
 
README.md
README.md
 
 
pyproject.toml
pyproject.toml
 
 

Repository files navigation

he-checks

Quiet failures in H&E image pipelines and datasets, and a check for each.

None raises an error, and each quietly changes what gets measured downstream.

  1. Macenko stain vectors that have collapsed into one. An SVD sign convention can put every tissue pixel on the wrap of arctan2, so the "haematoxylin" and "eosin" vectors come back a fraction of a degree apart. It is a known pitfall that established libraries guard against, but a hand-written estimator still runs without it. We found it in our own TCGA work: 0.17° between H and E, against about 14° once fixed. With numpy, an uncentred estimator without the sign check collapsed on all 60 TCGA colorectal tiles we tested.
  2. 25 TCGA colorectal slides whose stated pixel spacing is wrong. 17 TCGA-COAD and 8 TCGA-READ diagnostic slides are small derivative files. IDC states 0.5 µm/px for them; independent measurements put the true value near 0.9–1.3 µm/px, so each pixel covers roughly twice the stated width. In the widely used Kather TCGA tile archive their tiles are blurred 2.56× enlargements (checked on the 15 COAD archives we hold).
  3. Purple glass in CRC-VAL-HE-7K. All 847 background tiles of this standard benchmark, distributed already stain-normalised, are dark purple instead of near-white glass.

Install

pip install "he-checks @ git+https://github.com/parallaxmetrology/he-checks"

Python 3.9+, numpy and Pillow. Images can be uint8, uint16 or float (0–1 or 0–255), RGB or RGBA.

1. Check your stain estimator

import numpy as np
from PIL import Image
import hechecks as hc

tile = np.asarray(Image.open("tile.png").convert("RGB"))

hc.diagnose_image(tile)          # on the TCGA reference tile in docs/stain-sign.md:
# ImageDiagnosis(tissue_pixels=178417, share_negative_on_axis0=1.0, straddles_wrap=True,
#                naive_angle_deg=0.17, safe_angle_deg=14.5, status='degenerate')

hc.check_stain_matrix(my_pipeline.stain_matrix)        # a 2 x 3 matrix, row 0 = H
hc.check_estimator(my_pipeline.estimate, tiles)        # your estimator over many tiles
M = hc.macenko_stain_matrix(tile)                      # sign-safe reference estimate
he-checks stain tiles/*.png   # one JSON line per tile; exit 0 ok, 1 suspect or unreadable, 2 degenerate

diagnose_image runs the textbook uncentred estimator twice, as written and with the first axis oriented toward the tissue, and reports both. status describes the naive estimate: degenerate (H/E angle under 2°), suspect (under 5°) or ok. The thresholds are heuristics from TCGA tiles, where sign-safe estimates had medians of 14–16° and none fell under 10° in a 60-tile check; a tile that is nearly all one stain can be small for real reasons. Mechanism, numbers and limits: docs/stain-sign.md.

2. Flag the mis-scaled TCGA slides

hc.is_derivative_slide("TCGA-AA-3488-01Z-00-DX1")       # True
hc.is_derivative_slide("b8085eff-8407-4fd5-b2ba-70fa649aa07d")  # GDC file id: True
hc.derivative_slides()                                  # all 25 rows
he-checks tcga TCGA-AA-3488 TCGA-AA-3514    # exit code 1 if any is on the list

The list is also a plain CSV: data/tcga_derivative_slides.csv. Patient ids match the diagnostic slide only; the same patients' frozen sections are ordinary scans.

bearing on the 17 COAD slides cohort median, µm/px
scanner field grid in the scanned-area outline 0.90 (IQR 0.82–0.98)
tissue area 1.20
structure scale 1.26
grid ratio of a public tile archive cut from them 1.28
stated by IDC 0.5

We reported the slides to the IDC and GDC helpdesks on 6 November 2026. Per-slide values disagree with each other; use the cohort range, not a per-slide number. If you use physical scale (µm, magnification-matched tiles, nucleus size, cells per mm²), exclude these slides or treat their scale as unknown. Methods: docs/derivative-slides.md and the technical note.

3. The Kather colorectal tile collections

hc.is_derivative_slide("TCGA-AA-3496-01Z-00-DX1.B109A6F3-02E0-4181-B69A-00CBA758C074_(3663,2051).jpg")  # tile name: True
hc.tile_tint(background_tile)   # TileTint(mean_rgb=(123.2, 79.1, 134.2), ..., status='tinted')
he-checks tint BACK/*.tif     # one JSON line per tile; exit 1 if any is not neutral glass
  • TCGA tile archive (Zenodo 3784345). Tiles from the derivative slides were cut on a 200-px grid and enlarged to 512 px; tiles from regular site-AA scans were reduced from 1,101 px. Tile names start with the slide barcode, so the lookup above works on them. On the archives we hold, every tile from the 15 non-empty COAD derivative archives is flagged and no tile from the 167 other patients is.
  • CRC-VAL-HE-7K. tile_tint flags all 847 background tiles as tinted (mean RGB 123, 79, 134); 396 of 400 sampled background tiles from the unnormalised NCT-CRC-HE-100K-NONORM are neutral. Any brightness or tonal measure, and any comparison across normalised and unnormalised versions, is affected.

Details and sources: docs/kather-datasets.md.

What this does not do

  • It does not judge whether stain vectors are good, only whether they have collapsed.
  • It does not cover other normalisers (Reinhard, Vahadane, learned ones), or other TCGA projects.
  • It does not say any particular library has the sign problem; established ones correct the sign. Run the check on the code you actually use.
  • It does not give a calibrated pixel spacing for any single derivative slide. Nobody we know of has one.

Tests

pip install -e ".[dev]" && pytest

The tests build synthetic H&E tiles from known stain vectors, force the bad sign and check that the collapse is detected, check the slide list against the published note, and exercise the command line.

Contribute

  • Run check_estimator on the stain step of a pipeline you use and report what it finds, collapsed or not.
  • If you know how the 0.5 µm/px value was assigned to these slides, or whether full-resolution originals exist, open an issue.
  • Know another silent failure of this kind in H&E data? That is the most useful issue there is.

Part of Parallax Metrology

Deterministic structural measurement across domains. Siblings: visual-thinking-lens, structural-topology-kernel, how-measures-lie (nineteen ways an image measure returns a plausible, wrong number). Pathology work and its claim ledger: parallaxmetrology.com.

License and data

Code: MIT (LICENSE). Documentation: CC BY 4.0 (LICENSE-CONTENT). The slide list contains open-access TCGA metadata from GDC and IDC and no images.

Cite

See CITATION.cff. Russell Parrish, Parallax Metrology, with analysis carried out with Claude (Anthropic).

About

Quiet failures in H&E pipelines and colorectal datasets: Macenko stain vectors collapsed by an SVD sign convention, 25 TCGA slides (and their archive tiles) with ~2x wrong pixel spacing, and purple 'blank glass' in CRC-VAL-HE-7K.

www.parallaxmetrology.com/parallax_pathology_pm.html

Topics

computational-pathologydata-qualityhistologykather-datasetsmacenkoparallax-metrologystain-normalizationtcga

Resources

Readme
Activity