GV

GeezerVison

The World Wide Web, restored to 800 pixels of glory.

Home|About|Gaming cabinet|Archives|How it works|Starter sites

On this site

  • EasyEDA Pro MCP
  • Quick Start
  • AI Clients
  • Workflows
  • Tools
  • Upgrading
  • Changelog
  • GitHub
  • EasyEDA Pro Extension
  • DRC Rule Editing
  • Architecture
  • Safety Model
  • Troubleshooting
  • Repository Docs Index

This view

  • Original page
  • New address

GeezerVison is showing vlabsoft.org — Troubleshooting | EasyEDA Pro MCP

Troubleshooting ​

Quick diagnostics and fixes organized by symptom and error code.

Debugging & Diagnostics Checklist ​

Before diving into specific errors, run these two checks:

  1. From your AI client: ask the agent to run easyeda_doctor and inspect extension.connected, compatibility.compatible, and activeDocument.
  2. Inside EasyEDA Pro: click MCP Bridge -> Run Diagnostics (or MCP Bridge -> Show Status) in the top toolbar to see whether the extension is connected to ws://127.0.0.1:8765.

Common Symptoms ​

connected: false in easyeda_doctor ​

  1. Confirm EasyEDA Pro (>= 2.3.0) is open with a schematic or PCB tab loaded.
  2. Open Extensions -> Extensions Manager and verify EasyEDA MCP Bridge is imported and Allow interactive with external is enabled.
  3. Click MCP Bridge -> Reconnect in the EasyEDA Pro top toolbar.
  4. Run easyeda_doctor again.

No easyeda_* Tools Appear in the AI Client ​

  1. Build the server so dist/index.js exists: npm install && npm run setup:local.
  2. Confirm your client config points to the absolute path of dist/index.js (on Windows JSON files, escape backslashes: C:\\Users\\you\\...\\dist\\index.js).
  3. Restart or refresh your MCP client — most clients load the tool catalog once at startup.

WebSocket Bridge Fails to Connect (ws://127.0.0.1:8765) ​

  • Verify another stale MCP server process is not occupying a mismatched port, and that EASYEDA_MCP_WS_HOST / EASYEDA_MCP_WS_PORT were not changed on only one side.
  • Ensure local firewall or endpoint security software permits loopback (127.0.0.1) WebSocket connections.

Old Extension Version Reported After Upgrade ​

Rebuilding the repository does not automatically update an extension already imported into EasyEDA Pro:

  1. Import the updated build/dist/easyeda_mcp_bridge.eext in Extensions Manager.
  2. Re-enable Allow interactive with external if EasyEDA Pro reset the toggle.
  3. Click MCP Bridge -> Reconnect (or restart EasyEDA Pro if old callbacks remain cached).

DRC Tool Returns wrong_document or stale_edit ​

  • wrong_document: switch the active tab in EasyEDA Pro to the target PCB (documentType: 3); schematics, symbols, and footprints are rejected.
  • stale_edit: the PCB tab, WebSocket session, or underlying rules changed after easyeda_prepare_drc_edit. Run easyeda_prepare_drc_edit again to generate a fresh editId.

Schematic Snapshot Shows partial Confidence or Warnings ​

EasyEDA Pro may omit net names on raw schematic primitives in some sheets. Inspect the warnings array in easyeda_schematic_snapshot, narrow the query with easyeda_trace_component, and visually verify critical nets using easyeda_navigate_component.


Error Code Reference ​

Structured errors returned by the bridge include an errorCode field for deterministic recovery:

Error CodeCauseRemediation
api_unavailableRequired eda.* method is missing in your EasyEDA Pro versionUpgrade EasyEDA Pro (>= 2.3.0) and inspect capabilities in easyeda_get_context.
wrong_documentA PCB-only tool (such as DRC rules) was called while a schematic, symbol, or footprint tab was activeFocus the target PCB tab (documentType: 3) in EasyEDA Pro.
missing_document_identityActive PCB lacks project, document, or tab UUIDsSave and reopen the project tab inside EasyEDA Pro, then retry.
confirmation_requiredMutating action lacked the required approval phrase or exact CONFIRM editDrcRules <editId>Obtain human approval and pass the exact confirmation string.
configuration_existscreateConfiguration used a profile name that already existsChoose a new profile name (allowOverwrite is always false).
stale_editActive PCB, WebSocket session, or rule state changed after easyeda_prepare_drc_editRun easyeda_prepare_drc_edit again to generate a fresh preview.
edit_expiredPrepared DRC preview is older than 15 minutesPrepare and review a new DRC edit (easyeda_prepare_drc_edit).
edit_already_startedAttempted to execute the same editId more than onceCall easyeda_get_drc_edit_result to inspect the existing outcome.
drc_edit_outcome_unknownBridge timed out or disconnected after dispatching a DRC writeDo not auto-retry. Query easyeda_get_drc_edit_result and reread rules with easyeda_get_drc_rules.
You are visitor 01402792 — GeezerVison does not store the pages you look up.
Best viewed with Netscape Navigator 4.7 or Internet Explorer 6 at 800×600. No cookies required.