VoltDB supports eleven datatypes. When invoking stored procedures from different programming languages or queuing SQL
statements within a Java stored procedure, you must use an appropriate language-specific value and datatype for arguments
corresponding to placeholders in the query. This appendix provides the mapping of language-specific datatypes to the
corresponding VoltDB datatype.
In several cases, there are multiple possible language-specific datatypes that can be used. The following tables
highlight the best possible matches in bold.
F.1. Java and VoltDB Datatype Compatibility
Table F.1, “Java and VoltDB Datatype Compatibility” shows the compatible Java datatypes for each VoltDB datatype when:
In reverse, the table also shows which SQL datatype is used for the arguments and return values of user-defined
functions written in Java. The highlighted Java datatype listed in the second column results in the corresponding SQL
datatype being accepted or returned at runtime.
Note that when calling user-defined stored procedures written in Java, you can use additional datatypes, including
arrays and the VoltTable object, as arguments to the stored procedure, as long as the actual query invocations within the
stored procedure use the following datatypes. Within the stored procedure, when queuing SQL statements using the
voltdbQueueSql method, implicit type casting is not guaranteed so using the highlighted Java type is recommended.
VoltDB accepts both primitive numeric types (byte, short, int, and so on) and their reference type equivalents (Byte,
Short, Integer, etc.). The reference types can be useful, especially when passing null values, where you can send a Java
null. In most cases when using the primitive types, you must pass the largest possible negative value for the type in place
of null.
Table F.1. Java and VoltDB Datatype Compatibility
| SQL Datatype | Compatible Java Datatypes | Notes |
|---|
| TINYINT | byte/Byte
short/Short
int/Integer
long/Long
BigDecimal
String | Larger datatypes (short, int, long, and BigDecimal) are valid input types. However, VoltDB throws a
runtime error if the value exceeds the allowable range of a TINYINT. String input must be a properly
formatted text representation of an integer value in the correct range. |
| SMALLINT | byte/Byte
short/Short
int/Integer
long/Long
BigDecimal
String | Larger datatypes (int, long, and BigDecimal) are valid input types. However, VoltDB throws a runtime
error if the value exceeds the allowable range of a SMALLINT. String input must be a properly formatted
text representation of an integer value in the correct range. |
| INTEGER | byte/Byte
short/Short
int/Integer
long/Long
BigDecimal
String | Larger datatypes (long and BigDecimal) are valid input type. However, VoltDB throws a runtime error if
the value exceeds the allowable range of an INTEGER. String input must be a properly formatted text
representation of an integer value in the correct range. |
| BIGINT | byte/Byte
short/Short
int/Integer
long/Long
BigDecimal
String | String input must be a properly formatted text representation of an integer value in the correct
range. |
| FLOAT | double/Double
byte/Byte
short/Short
int/Integer
long/Long
BigDecimal
String | Because of the difference in how numbers are represented in the two types, there can be a loss of
precision when using BigDecimal as input to a FLOAT value. String input must be a properly formatted
text representation of a floating point value. |
| DECIMAL | BigDecimal
double/Double
byte/Byte
short/Short
int/Integer
long/Long
String | String input must be a properly formatted text representation of a decimal number. |
| GEOGRAPHY | | Geospatial input should be converted from Well Known Text (WKT) to a VoltDB native format either using
the GeographyValue.fromWKT() method or by passing a String and using the POLYGONFROMTEXT function within the SQL
statement. |
| GEOGRAPHY_POINT | | Geospatial input should be converted from Well Known Text (WKT) to a VoltDB native format either using
the GeographyPointValue.fromWKT() method or by passing a String and using the POINTFROMTEXT function within the SQL
statement. |
| VARCHAR() | String
byte[]
byte/Byte
short/Short
int/Integer
long/Long
BigDecimal
VoltDB TimestampType | Byte arrays are interpreted as UTF-8 encoded string values. String objects can use other
encodings. Numeric and timestamp values are converted to their string representation. For example, the
double value 13.25 is interpreted as "13.25" when converted to a VARCHAR. |
| VARBINARY() | | String input is interpreted as a hex-encoded binary value. For ByteBuffers, the starting
position and limit properties are ignored and the entire buffer is interpreted as a byte array starting in position
zero. |
| TIMESTAMP | VoltDB TimestampType
int/Integer
long/Long
String | For String variables, the text must be formatted as either YYYY-MM-DD hh.mm.ss.nnnnnn or
just the date portion YYYY-MM-DD. |