GeezerVison is showing github.com — task(cluster): circuit spec + electrician brief · Issue #1103 · developing-today/code
task(cluster): circuit spec + electrician brief #1103Labels area/infraInfrastructure, deployment, and operationseffort/sSmall: expected under 2 hours of workepic/lab-clusterEpic: lab-cluster - all issues of this effort carry itmeta/enrichedIntake review done: acceptance criteria, links, and normalized labels addedmode/onlineFully doable remotely: design, config, code, cloud DescriptionCircuit spec + electrician brief
Parent epic: #1083 (basement cluster program). Project home: planning/roadmaps/basement-cluster.md.
Write the spec the electrician quotes against: a few dedicated 20A circuits, each on its own breaker, from the panel across the open/unfinished basement (past ~3 simple walls, along the ceiling) to the server room; existing cable paths may be reusable; Drew prefers direct dedicated runs over the earlier UPS-breaker drop. Include the load estimate for the first 3-5 machines and headroom for 12.
Acceptance: one-page brief ready to send; load math shown. Activitydeveloping-today commented on Oct 27, 2026 dezren39 commented on Oct 29, 2026 🤖 Agent note · done (triage verdict: CONFIRMED — routed to a follow-up packet)
- Agent: queue worker (repo-worker-code), Lane C shift
- Session / ID: queue task 2380 (triage)
- Found via: queue claim
- Task: Triage task(cluster): circuit spec + electrician brief #1103 against current main and route it.
- Verdict — CONFIRMED and routable: Verified on main 39e8410 (2026-10-29T01:57Z): no circuit spec or electrician brief exists anywhere in the repo (code search for "electrician" returns nothing), and
planning/roadmaps/basement-cluster.md still lists basement power & space (epic(cluster): basement power & space #1083) as "planned". Unlike its sibling task(cluster): define the golden firmware/settings baseline #1100, this task is NOT blocked on the escalated stats work: the issue itself pins every design input (dedicated 20A circuits, own breaker each, ceiling route across the open basement past ~3 walls, reusable existing cable paths, direct runs preferred over the UPS-breaker drop, 3–5 machines now with headroom for 12). The brief can be written now as long as the per-machine draw is named as a planning assumption (measured values land later via task(cluster): gather stats - core Threadripper machines #1095) and panel specifics are listed as site-visit open items instead of invented.
- Route: follow-up small_fix packet enqueued to repo-health-code-pilot — dedupe key
repo-health:v1:fix:developing-today/code:issue:1103 — scoped to: write the one-page brief, show the load math (totals for 3–5 and for 12 machines, 80% continuous derating → 1920W usable per 20A/120V circuit, circuit count derived), list site-visit confirmations as open items, link the brief from the roadmap. Its output is what task(cluster): engage an electrician (quotes + schedule) #1104 (engage an electrician, user/owned) will send.
- Expectation: triage done; the follow-up packet is queued (
queue/queued label mirrors it still being open work).
- Links: epic epic(cluster): basement power & space #1083 · consumer task(cluster): engage an electrician (quotes + schedule) #1104 · roadmap
planning/roadmaps/basement-cluster.md
dezren39 commented on Oct 30, 2026
Agent note — picked up (resume)
dezren39 commented on Oct 30, 2026
Agent note — parked (merge queue)
dezren39 commented on Oct 30, 2026
🤖 Agent note · done — brief merged
- Agent: queue worker (
repo-worker-code), OpenChamber scheduled lane (origin openchamber-scheduled-lane)
- Task: 2998 (docs: circuit spec + electrician brief), resumed from
awaiting_ci park
- Fresh state: PR #2367 MERGED 2026-10-30T03:36:30Z at
bbddddd2; all checks had passed on head afdc3097, Codex reported no findings.
- Deliverable verified on
main at bbddddd2: planning/roadmaps/basement-cluster-electrician-brief.md (56 lines) exists; planning/roadmaps/basement-cluster.md links it from the basement power/space row; load math is internally consistent (600 W/machine assumption, 1920 W usable per 20A/120V circuit → 3 machines 1800 W/1 circuit, 5 machines 3000 W/2, 12 machines 7200 W/4); route and preferences are carried in substance (dedicated runs, own breaker each, ceiling route past ~3 walls, existing paths reusable, no UPS-breaker drop); site-visit unknowns are listed as open items rather than invented.
- Next: task(cluster): engage an electrician (quotes + schedule) #1104 (engage an electrician,
user/owned) now has the brief to send; no action taken there by this lane.
- Closing: issue closed as completed; queue labels stripped.
MetadataMetadataarea/infraInfrastructure, deployment, and operationseffort/sSmall: expected under 2 hours of workepic/lab-clusterEpic: lab-cluster - all issues of this effort carry itmeta/enrichedIntake review done: acceptance criteria, links, and normalized labels addedmode/onlineFully doable remotely: design, config, code, cloud DevelopmentNo branches or pull requestsIssue actions
|